摘要: PowerEdge 2600 LED Reference Table 1

本文可能採用自動翻譯。如果您對翻譯品質有任何寶貴意見,請使用此頁面底部的表單告訴我們,謝謝。

文章內容


症狀

PowerEdge 2600 LED Reference Table 1
 

The following troubleshooting LED codes are valid while the server is not able to complete POST. If the troubleshooting LEDs are on or flashing, refer to the LED definitions and instructions in Table 1.   

 

  NOTE:  Record and troubleshoot the first LED code in the sequence.  This is the most important code to follow when troubleshooting this system.  If you were unable to record the first code, completely power off the server and power it back on to record the first LED.

 

 

 

  NOTE: 

The troubleshooting LEDs also flash codes when the device in question has a hardware fault.

 

 

LED1

LED2

LED3

LED4

LED5

Problem

 

Off

Off

Off

Off

Off

AC power not present or bad +3.3V_AUX or PDB not connected

 

Blink

Off

Off

Off

On

Control Panel Cable Not Present

 

Blink

Off

Off

On

Off

Back Plane Cable Not Present

 

Blink

Off

Off

On

On

VRM1 missing

 

Blink

Off

On

Off

Off

CPU1 missing

 

Blink

Off

On

Off

On

CPU2 present but VRM2 missing

 

Blink

Off

On

On

Off

VRM2 present but CPU2 missing

 

Blink

Off

On

On

On

VRM1 & VRM2 vendors mismatch

 

Blink

On

Off

Off

Off

CPU1 & CPU2 core voltage (VID) mismatch

 

Blink

On

Off

Off

On

CPU1 & CPU2 bus frequency mismatch

 

Blink

On

Off

On

Off

DDR200 memory in 533MHz

 

Blink

On

Off

On

On

CPU1 heat sink not installed properly - Thermtrip on CPU1 

 

Blink

On

On

Off

Off

CPU2 heat sink not installed properly - Thermtrip on CPU2 

 

Off

Blink

Off

Off

On

PS_ON# from the ICH3 not happening

 

Off

Blink

Off

On

Off

+12V bad or missing - power supply not turning ON

 

Off

Blink

Off

On

On

+1.2V is not good

 

Off

Blink

On

Off

Off

+1.8V is not good

 

Off

Blink

On

Off

On

+1.25V is not good

 

Off

Blink

On

On

Off

+2.5V is not good

 

Off

Blink

On

On

On

+3.3V is not good

 

On

Blink

Off

Off

Off

+3.3V_PCI is not good

 

On

Blink

Off

Off

On

+5V is not good

 

On

Blink

Off

On

Off

System power good missing - bad U6009

 

On

Blink

Off

On

On

Standby power good missing - bad +5V_AUX or +1.8V_AUX

 

On

Blink

On

Off

Off

CPU1 VRM is not good

 

On

Blink

On

Off

On

VRM2 VRM is not good

 

Off

Off

Blink

Off

On

CPU POR is not high - North bridge is not happy

Off

Off

Blink

On

On

ICH3 PCI Reset is not high - ICH3 is not happy

 

Table 1 - PowerEdge 2600 LED Codes



原因

 

解析度

 

文章屬性


受影響的產品

PowerEdge 2600

上次發佈日期

30 3月 2024

版本

4

文章類型

Solution