Steps for installing FTOS on Dell Open Networking (ON) switches.


1. Log into the ONIE loader on the switch by pressing ESC during the boot process.



2. Choose the ONIE loader from the boot menu.

Note: This example below already has an FTOS install.



3. You will likely see continual messages seen below. To stop these run the command onie-discovery-stop.



4. Run the command fdisk -l to view the current storage locations. This will help determine where the USB is. In this case we are "/dev/sdb1" For the following steps, be sure to reference the proper location.



5. Format the USB by running the command mkfs.vfat /dev/sdb1


6. Now you can remove the USB and move it to a workstation to copy the OS files to. Remember that for this installation, the filename should start with "ONIE".
7. Create a directory for the USB to mount to. mkdir /mnt/usb



8. Mount the USB to the newly created directory: mount -t vfat /dev/sdb1 /mnt/usb



9. Navigate to the directory that we just mounted the USB drive. cd /mnt/usb



10. From here you can run ls and you should see the OS file listed.



11. Now we can install the OS. "onie-nos-install ONIE-FTOS-SI- ON-9.9.0.0.bin" (be sure to use the correct filename) (filenames are case sensitive).






Article ID: HOW11548

Last Date Modified: 06/04/2018 04:43 PM


Rate this article

Accurate
Useful
Easy to understand
Was this article helpful?
Yes No
Send us feedback
Comments cannot contain these special characters: <>()\
Sorry, our feedback system is currently down. Please try again later.

Thank you for your feedback.