Prerequisites
Follow the safety guidelines listed in Safety instructions.
Follow the procedure listed in Before working inside your system:
Power off the sled.
Remove the sled from the enclosure.
Remove the 2U sled from 1U node.
Route the fan cables properly through the fan guard and disconnect the fan cable connected to the connector on the power distribution board (PDB) of the 1U sled.
NOTE: Fan 1, 2, 3 and 4 are connected to the 1U PDB.
Pull slightly to disengage the fan cable from the fan guard and then lift the fan module out of the fan cage.
NOTE: The airflow directional arrow outward on the fan indicates Reverse-Air-Flow (RAF).
Installing a cooling fan on 1U sled:
Lower the fan module into the cage until it is seated firmly.
NOTE: The airflow directional arrow outward on the fan indicates Reverse-Air-Flow (RAF).
Route the fan cables properly through the fan guard and connect the cable to the connector on the power distribution board (PDB) of the 1U sled as shown in the image below.
NOTE: Fan 1, 2, 3 and 4 are connected to the 1U PDB.
Install the 2U sled on 1U node.
After working inside your system:
Reconnect the peripherals and connect the system to the electrical outlet, and then power on the system.