Prerequisites
Follow the safety guidelines listed in the Safety instructions.
Power off the system and all attached peripherals.
Disconnect the system from the electrical outlet and disconnect the peripherals.
If applicable, remove the system from the rack.
Remove the system cover.
Removing the BOSS-N1 module:
Pull and lift the BOSS-N1 card carrier retention latch lock to open.
Slide the BOSS-N1 card carrier out.
Using the Phillips #1 screwdriver remove the M3 x 0.5 x 4.5 mm screw that secures the M.2 SSD to the BOSS-N1 card carrier.
Slide the M.2 SSD out from the BOSS-N1 card carrier.
Disconnect the BOSS-N1 power and signal cable from the system board.
Using the Phillips #1 screwdriver remove the M3 x 0.5 x 4.5 mm screw that secures the BOSS-N1 module on Riser 1.
Slide the BOSS-N1 module towards the front of the chassis and lift the module.
Remove the BOSS-N1 power and signal cable from the BOSS-N1 module.
Installing the BOSS-N1 module:
Connect the BOSS-N1 power and signal cables to the connectors on the BOSS-N1 module.
Align the BOSS-N1 module at an angle with the controller card module slot.
Insert the BOSS-N1 module and push the module horizontally towards the rear of the system until firmly seated.
Using the Phillips #1 screwdriver, secure the BOSS-N1 module with the M3 x 0.5 x 4.5 mm screw.
Connect the BOSS-N1 power and signal cable to the connectors on the system board.
Align the M.2 SSD at an angle with the BOSS-N1 card carrier.
Insert the M.2 SSD until it is firmly seated in the BOSS-N1 card carrier.
Using the Phillips #1 screwdriver, secure the M.2 SSD on the BOSS-N1 card carrier with the M3 x 0.5 x 4.5 mm screw.
Slide the BOSS-N1 card carrier into the BOSS-N1 module slot.
Close the BOSS-N1 card carrier release latch to lock the carrier in place.