Treiberdetails

Toshiba KXG50ZNV256G/KXG50ZNV512G/KXG50ZNV1T02 non-SED Solid State Drive Firmware Update

This package provides the firmware for Toshiba KXG50ZNV256G 256GB, KXG50ZNV512G 512GB and KXG50ZNV1T02 1TB non-SED M.2 2280, Revision AADA4106. Storage firmware is a microcode that is embedded on storage devices such as hard drives or solid-state drives. The firmware manages the functionality of the devices. This package is supported on Alienware, Inspiron, Latitude, OptiPlex, Precision, Vostro, and XPS systems that run Windows 7, Windows 8, Windows 8.1, and Windows 10 operating systems. The package improves the performance of the solid-state drive (SSD) by distributing power into the SSD efficiently according to the power state of the system.

Fehlerkorrekturen und Verbesserungen

Fixes:
- N/A

Enhancements:
- Improves the performance of the solid-state drive (SSD) by distributing power into the SSD efficiently according to the power state of the system.

Version

Version AADA4106, A00

Kategorie

Serial ATA

Veröffentlichungsdatum:

22 Jan 2019

Letzte Aktualisierung:

22 Jan 2019

Wichtigkeit

Verfügbare Formate

Dateiformat:Hard-Drive
Dateiname:Toshiba KXG50ZNV256G_KXG50ZNV512G_KXG50ZNV1T02 MFW44_ZPE.exe
Download-Art:HTTP
Dateigröße: 3 MB
Beschreibung des Dateiformats:Diese Datei umfasst einen Satz komprimierter oder gezippter Dateien. Laden Sie die ZIP-Datei in einen Ordner auf der Festplatte herunter und entpacken Sie sie mit einem Doppelklick. Befolgen Sie die Anweisungen, um die Installation abzuschließen.
To ensure the integrity of your download, please verify the checksum value.
MD5:
95a02da562fc9b8aaa7e8d6b90b4c3c8
SHA1:
976929d4b421465045560f2ff8e73e5eb8c301d1
SHA-256:
adcc4aaccb6e985892149b5bb3e991344b013db54df5fe4bbdc9b15ce6586d65

Mit dem Download stimmen Sie der Dell Softwarelizenzvereinbarung (in Englisch)  zu.

Version
AADA4105,A00 31 Mai 201808:07:11
Kompatible Systeme
Unterstützte Betriebssysteme
Windows 7, 32-bit
Windows 7, 64-bit
Windows 8, 32-bit
Windows 8, 64-bit
Windows 8.1, 32-bit
Windows 8.1, 64-bit
Windows 10, 32-bit
Windows 10, 64-bit
Sie suchen nach einem anderen Betriebssystem? Liste der von Dell unterstützten Betriebssysteme anzeigen
Gilt für
TOSHIBA XG5 1TB PCIE NVME 2280 SSD (CLASS 40)
TOSHIBA XG5 256G PCIE NVME 2280 SSD (CLASS 40)
TOSHIBA XG5 512G PCIE NVME 2280 SSD (CLASS 40)
Installationsanweisungen
Note:
You are advised to back up the data in the system and close all open applications. It is also recommended to connect the power cable if it is not a desktop and disconnect all external storage devices.

Firmware upgrade through the Windows utility

Download
1. Click Download File to download the file.
2. When download is complete, run Toshiba KXG50ZNV256G_KXG50ZNV512G_KXG50ZNV1T02 MFW44_ZPE.exe to unzip this file.
3. Select Continue and take note of the unzip location.

Upgrade Procedure
1. Go to the folder where you have unzipped the package.
2. Right-click on the file that is named XG5-AADA4106-64bit.exe and select Run as administrator to run the file with administrator privilege.
3. Review the License Agreement. If you agree with it, click I ACCEPT and then click Next >.
Tips: You can save End User License Agreement (EULA) by clicking Save EULA as Text.
4. The Welcome window is displayed with a warning message at the bottom. Read the warning message carefully and click Next > to continue.
5. A window is displayed where you can select the solid-state drive (SSD) to be updated. You can select only those SSDs that are targeted for this update on the FW Update Tool.
6. Check the box next to applicable SSDs to target. Click Next > to continue.
7. Before You Begin window is displayed at this stage. Read the instructions carefully. If complied, check the box for Yes, I did and click Next > to continue.
8. Firmware update operation is initiated automatically. Once the update completion message is displayed, click Shutdown to shut down the system.
9. Since the shutdown is initiated through FW update utility, below warning message is displayed before it shuts down.
If your system has unsaved data, save everything and close all applications respectively.
If the system does not shut down automatically, shut it down manually.

New firmware is applied when you power on the system. To confirm whether the firmware update was successful, repeat the upgrade procedure steps from 1 to 5. Present firmware version is displayed against Current Firmware.
Wichtige Informationen
Dell recommends that you back up your data before performing this update. Do not interrupt your system during the firmware upgrade process. If the firmware upgrade process is interrupted, the solid-state drive may not function properly.
x
Warnung: Um eine Beschädigung Ihres Computers zu vermeiden, sollten Sie ihn während einer BIOS-Aktualisierung niemals ausschalten oder von der Stromquelle trennen. Während der Aktualisierung wird Ihr Computer neu gestartet und Ihnen wird kurzzeitig ein schwarzer Bildschirm angezeigt.

Dieser Treiber wurde sowohl von unabhängigen Softwareanbietern (Independent Software Vendors, ISV) als auch von Dell für die von Ihrem Gerät unterstützten Betriebssysteme, Grafikkarten und Anwendungen getestet, um maximale Kompatibilität und Leistung zu gewährleisten. Details

Dell empfiehlt, diese Aktualisierung während Ihres nächsten planmäßigen Aktualisierungszyklus durchzuführen. Diese Aktualisierung enthält Funktionsverbesserungen oder -änderungen, die dafür sorgen, dass Ihre Systemsoftware aktuell und kompatibel mit anderen Systemmodulen (Firmware, BIOS, Treiber und Software) bleibt.