Dell PowerEdge C6220 II BMC firmware

Restart required Installed This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This package provides BMC Firmware and is supported on Dell PowerEdge PEC6220II running the following Operating System: Windows Server 2008 R2, 2012 and 2012 R2, Linux RHEL 6.3, RHEL6.4, SLES 11 update 2 and SLES 11 update 3, MS-DOS.
Recommended

Check compatibility

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Fixes
- BMC did not generate de-assertion event properly when unplug and plug FAN module.
- User sometimes not be able to read BMC IP address in BIOS setup menu.
- iKVM will lose frame rate and bandwidth via Shared-NIC during DC cycle.
- SEL almost full recored would display several times when AC cycle.
- BMC firmware update is abnormal and stopped update process.
- Added "simplified" address checking for IPv6 static address.
- If system linking down time is less than the linking down threshold value (5 seconds), the IP address will be released and won't be recovered.
- If DHCP allows for "::/0" as IP Address 2, then static should also accept "::/0" for IP Address2.
- Updating BMC with SOCflash utility cause "Pre-Init Time-stamp" in sel continuously.

Enhancements
- Enhance BMC semaphore process.
- Add link status debounce feature for avoiding link status bouncing during DC cycle.
- Support GUID synchronize with SMBIOS type 1 UUID.
- Apply new SOCflash utility for f/w update.
Read More

Version

2.26, 2.26

Release date

07 Feb 2014

Download Type

Firmware

Category

Embedded Server Management

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
Available formats View Important Information

File Format: Update Package for MS Windows 32-Bit
File Name: C6220-II_ESM_Firmware_NVRV0_WN32_2.26.EXE
File Size: 22.39 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
2cf27a0a4dea7483d3727e5b083e23ae
SHA1:
16cb18b8fc2b950719c3ae46a348a6228a05516b
SHA-256:
94bf7809de9644810b11785b774a087daef123252a5a6716274f909a00dcf6f9

File Format: One or more self extracting disk images inside of a self extracting zip
File Name: PEC6220IIBMC226.exe
File Size: 152.4 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, then double-click it to unzip the set of files. Follow the instructions to complete the installation.
To ensure the integrity of your download, please verify the checksum value.
MD5:
c81ef572490ae85304f8b39b9428a9c3
SHA1:
209142f57a0e9c1aeb70c9375080488a67f5102c
SHA-256:
4ba715dbc225d9999dc6a1a3917a3e50f3b93073db9dc64656369e45bc830ded

File Format: A GnuPG file which contains a cryptographic signature
File Name: C6220-II_ESM_Firmware_NVRV0_LN32_2.26.BIN.sign
File Size: 189 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
10017d2d61e9e2c7005319cbf0008232
SHA1:
fcc4ddd1a49d60b0622a23f985257729c1e8b2ef
SHA-256:
210714fa6b83a32bfe959d65a64f7618d3f255c0ca579d96bc8b17b37850f4a9

File Format: A text file containing customer friendly fixes and enhancements information
File Name: EndUserLicenseAgreementTypeS_Rev.040512.txt
File Size: 11.4 KB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file format contains plain text which can be viewed with a standard text editor.
To ensure the integrity of your download, please verify the checksum value.
MD5:
c2ffe409366d225552ac6ed58f206b58
SHA1:
88522584d2ed8711c12c71ae9e569116a26e7b0a
SHA-256:
b85aae437264a3f053c9efec6b47fa1ba6610de28b749a06c2fec3dfc87bf333

File Format: Update Package for Red Hat Linux
File Name: C6220-II_ESM_Firmware_NVRV0_LN32_2.26.BIN
File Size: 17.46 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
1dd84a411d00d02b9ee2d80f9fa41ded
SHA1:
fa68a13116f44cd43a35786b1a9ac911c803ec62
SHA-256:
65adea4fb636257fc2fa6e8b844960502ba52754e4316d8b7afe2d2cffa2b599

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
Limitation:
In this version, BMC added link status debunce function in share NIC for avoiding NIC link state boucing problem during DC cycle. BMC will skip NIC link status change within 5 seconds, so please do not replug LAN cable within 5 seconds.

Do not roll back to old version after you update to V1.14 already.
If you want to flash to old version, please use socflash.

BMC firmware might have version dependency with chassis firmware. Before update BMC firmware, please check related chassis FAN Controller Board firmware release package first.

KCSflash - use *.dcs for firmware update
NOTE: Since the KCS update utility may refer to some dynamic linked library files, KCSflash directory structure must be maintained to update BMC via KCS channel when it is extracted from the package.

=================================================================
Dos: Execute FBMC.bat in the folder, and utility will show the steps to upgrade BMC F/W.
=================================================================
Linux: Execute FBMC.sh in the folder, and utility will show the steps to upgrade BMC F/W.
=================================================================
Windows: Execute FBMC.bat in the folder, and utility will show the steps to upgrade BMC F/W.
=================================================================
Web Upgrade: Update via web by using *.dcs file under KCSflash/dos folder.
Note that Web upgrade is only for the current BMC is higher than V1.14.
=================================================================
Most usful parameter of DCSFWUD.EXE:
-e=value Specify enitity ID of image.
-f, -force Force reboot system or BMC without prompt user.
-o=value Specify the Install Options. Optional.
0 - Do not preserve config (default). (update BMC with default value)
1 - Preserve config. (update BMC with previous configuration)
-help Search for all parameter
=================================================================
Socflash - use allv***.bin for firmware update
Dell BMC Firmware
Download
1. Click 'Download File' to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.

This new version changed BMC shared NIC behavior from bonding mode to NCSI mode. That means you can specify the specific NCSI port (NIC1 or NIC2) as BMC shared NIC. Due to this change, if you're updating via KCS (fbmc.sh) instead of running DUP, it would perform "restore LAN setting to default" to enable this new feature. Please check your network setting after firmware update to confirm if there is any setting changed by this.

If you're updating BMC by DUP (without configuration preserved), Shared NIC2 MAC will be restored to default MAC address. It did not affect the normal operation on shared NIC1. However, if you would like to apply NIC2 as BMC shared NIC, you should program the MAC address again manually by IPMI command.

1. #Get reservation ID
ipmitool raw 0x30 0x01

2. #switch to NIC 2
ipmitool raw 0x30 0x03 0x[reservation ID from first step] 0x02 0x02 0x00 0x00 0x00 0x01 0x02

3. #Enter manufacturing test mode
ipmitool raw 0x06 0x05 0x64 0x52 0x45 0x4d 0x24 0x73 0x74 0x38

4. #Program MAC address for NIC 2 (assuming MAC address 00:11:22:33:44:56)
ipmitool 0x20 0x30 0x01 0x01 0x05 0x00 0x11 0x22 0x33 0x44 0x56
(The last 6 bytes are MAC address)

Reboot will be required

Drivers help and tutorials