Fixes & Enhancements

Enhancements:
N/A
Fixes:
- Fix for issues that cause iDRAC7 sluggish responsiveness after a prolonged period of time (approx. 45-100 days, depending on the usage). In some cases, if the iDRAC is not reset, the iDRAC may become unresponsive and requires a server AC Power on reset. This issue was introduced in firmware release 1.50.50 and fixed in 1.56.55.
-1.57.57 includes an urgent fix for Rack and Tower PSU loss of redundancy that does not impact Blades and VRTX. (This release is not urgent for Blade and VRTX customers.)
This release fixes issues present in these releases:
- 1.50.50
- 1.51.51
- 1.51.52
- 1.55.55
- 1.56.55
- Keyboard and Mouse does not work in WinPE 810 through iDRAC Virtual Console.
- Keyboard presses and iDRAC Virtual Console macro actions are not passed to Windows 2012 R2 operating system through iDRAC Virtual Console.
- SNMP v2 and SNMP v3 walk of the iDRAC7 MIB times out.
- SNMP v3 only works with the default password for USER2.
- For the iDRAC admin user2, the SNMP password changes after iDRAC reboot.
- Link tuning error occurs when enabling ports 3 and 4 through BIOS attribute.
- While creating Virtual Disk using WSMAN commands for multiple RAID levels (5,50,60), WSMAN command fails with NULL values for the created Virtual Disk.
- After removing and reinserting the Delta HVDC PSU, "Incorrectly configured PSU" message is logged in the SEL.
- In shared LOM mode, when copying huge data from the management system to the host operating system, ping command times out for the iDRAC IP.
- Support for Delta HVDC PSU hot plug.
- XmlCleanupParser crashes the FullFW processing during SECUPD process and CFI scripts does not freeze BIOS with DUP error.
- CPU throttles on 115W IVB CPUs.
Read More

Version

1.57.57, A00

Release date

06 May 2014

Download Type

Firmware

Category

Embedded Server Management

Importance

Urgent
Dell Technologies highly recommends applying this important update as soon as possible. The update contains critical bug fixes and changes to improve functionality, reliability, and stability of your Dell system. It may also include security fixes and other feature enhancements.
Available formats View Important Information

File Format: Update Package for MS Windows 64-Bit.
File Name: ESM_Firmware_XH6FX_WN64_1.57.57_A00.EXE
File Size: 77.23 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
To ensure the integrity of your download, please verify the checksum value.
MD5:
020420ef97d807e4b296a3397eb6c36b
SHA1:
64aed36739487e04b13716d37081d892f38d553d
SHA-256:
d0ca879d771e9cd0814da5737e28eaca9c595c4bc847ca58d4421cb101813d20

File Format: An application
File Name: iDRAC7__1.57.57__A00.exe
File Size: 59.72 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Application
To ensure the integrity of your download, please verify the checksum value.
MD5:
2ccc457edb102ffccea88220534300bb
SHA1:
747ec160a9941d4d5332642816dae38d9b1b4e54
SHA-256:
caf6e6da3403140e596b3b78007e09088dfc4c10a7b49b41276bf1e0353d2e72

File Format: A GnuPG file which contains a cryptographic signature
File Name: ESM_Firmware_XH6FX_LN_1.57.57_A00.BIN.sign
File Size: 189 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
1c94ba36ebba2825dacfae5c09ca3b72
SHA1:
a1b51eee2155a9d4d10f2f33043c0981b88c9e9c
SHA-256:
2da07be8272febe6370d50e9a3fc6c417cd2cf0fd6d415e94a2271e1fd136b87

File Format: An archive of PDF files to provide help and procedural information to the customers
File Name: iDRAC7_1 57 57_A_ReleaseNotes.pdf
File Size: 237.46 KB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This format consists of an archive of PDF files used to provide help and procedural information to the customer. It is necessary to install the Adobe Acrobat Reader first to view the files in this archive.
To ensure the integrity of your download, please verify the checksum value.
MD5:
2dffdc04f32f39a4b8d795574e03e830
SHA1:
f8b896643ad7664bef7c30c00baed91b63d84457
SHA-256:
Not available

File Format: External release notes
File Name: iDRAC7_1.57.57_A_ReleaseNotes.txt
File Size: 80.17 KB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file format contains plain text which can be viewed with a standard text editor.
To ensure the integrity of your download, please verify the checksum value.
MD5:
6e241e3da089dd4c38120f8db4d3acbd
SHA1:
17d4ff3676bfc9d40f65390dcf512c2aa94b07dd
SHA-256:
Not available

File Format: Update Package for MS Windows 32-Bit
File Name: ESM_Firmware_XH6FX_WN32_1.57.57_A00.EXE
File Size: 69.69 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
c7df2cfa8a387ec6d5376f0a60b554fa
SHA1:
5ab1815d4f86446d11815dbccd776ddfecf678a7
SHA-256:
084f1b462e9ad1be3f0d473b487e65e8ab114500595a7bd01c0f7671780e24f5

File Format: Update Package for Red Hat Linux
File Name: ESM_Firmware_XH6FX_LN_1.57.57_A00.BIN
File Size: 64.56 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
0dddd818c0e10abc69d0a0e4802632c1
SHA1:
fbb1857a341f7452a27bd3933365669b3fb0dd38
SHA-256:
8168fa4eb615f617df98a76d8acba0ab9e1a0992af536a5e363558f1c2412eb6

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
Fix for issues that cause iDRAC7 sluggish responsiveness after a prolonged period of time (approx. 45-100 days, depending on the usage). In some cases, if the iDRAC is not reset, the iDRAC may become unresponsive and requires a server AC Power on reset. This issue was introduced in firmware release 1.50.50 and fixed in 1.56.55.
1.57.57 includes an urgent fix for Rack and Tower PSU loss of redundancy that does not impact Blades and VRTX. (This release is not urgent for Blade and VRTX customers.)
This release fixes issues present in these releases:
- 1.50.50
- 1.51.51
- 1.51.52
- 1.55.55
- 1.56.55
As a reminder, Dell always recommends you clear your browser cache(s) after updating the iDRAC7 firmware.
iDRAC with Lifecycle Controller
Download
1. Click Download Now to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update

Drivers help and tutorials