Download Files
File Format: Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
File Name: SAS-RAID_Firmware_1DHXW_WN64_52.30.0-6347_A05.EXE
File size: 24.36 MB
To ensure the integrity of your download, please verify the checksum value.
MD5: a267b3f871cbfba22f71f19e2e12679f
SHA1: 6f7654f76e98ba67e732b09fe548b3df4c57fda5
SHA-256: 4bff067224f9752cf6c0d29086776a697095ecf63551e67e1ed51c55aeca846e
File Format: The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
File Name: SAS-RAID_Firmware_1DHXW_LN64_52.30.0-6347_A05.BIN.sign
File size: 842 Bytes
To ensure the integrity of your download, please verify the checksum value.
MD5: c89702e8c2bd72564d00a9fd94edbdef
SHA1: bce81b852acf8ffdea837a0cdb51b2157d9a440c
SHA-256: 2fbcba1894d8f9b9a29b599135747a0e41ca66545def85133b137e5699dcef42
File Format: This file format contains plain text which can be viewed with a standard text editor.
File Name: SAS_RAID_Firmware_11.6.1_52.30.0-6347_RELNOTES.txt
File size: 15.43 KB
To ensure the integrity of your download, please verify the checksum value.
MD5: 6c8adc7bbce729a9aaf6f75197048aa9
SHA1: a1127ff5c377714ba3980c1f59d318c678b32139
SHA-256: 87999c1954c5ad4e910e7cedb25938919c9a6896676db43ee4358bc7ca6f4eb6
File Format: Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.<br /><b>Note:</b> Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
File Name: SAS-RAID_Firmware_1DHXW_LN64_52.30.0-6347_A05.BIN
File size: 14.54 MB
To ensure the integrity of your download, please verify the checksum value.
MD5: c756e6d40e16873c30242ed1fe9752f0
SHA1: aa5a848ffe4a7d2d2e7847ff2185d89f5b26980c
SHA-256: 54160a4b71ea4dc58e49916360dbc4a889310a93251a12c119cf8c9b8bee4a20
Fixes & Enhancements
Stability enhancements
reduced exposure to driver health protocol events resulting in UEFI0116 events
improved package layout for better iDrac processing to reduce errors while flashing
Fixed an issue with legacy BIOS boot mode
Important Information
After the firmware update, it is crucial to perform a complete graceful shutdown to power off of the system, followed by a power on to enable the new firmware.
A warm reboot will NOT activate the updated firmware.
If iDrac/LC is used to perform the update, a graceful shutdown to power off after the update is still required.
Important Information for Update Packages for Microsoft Windows
* Do not run other applications while executing Update Packages.
* Do not run storage controller update packages if the controller is in use by other applications.
The firmware upgrade may fail if any of the RAID controllers in the system are performing an I/O background task (that is, consistency check, background initialization, rebuild, or reconstruction). Allow the background task to complete before attempting to upgrade the firmware. Patrol Read tasks will not affect a firmware upgrade.
Important Information for Update Packages for Linux
* Do not run other applications while executing Update Packages.
* If the following error occurs, "Error while loading shared libraries: libstdc++.so.5: cannot open shared object file: No such file or directory", you must install the compatibility libraries from "www.redhat.com" or from the Red Hat CD. To install the compatibility libraries, use the following command: "RPM -ih compat-libstdc++-33-3.2.3-47.3.i386.rpm"
* When Update Packages stop abruptly due to a power outage or abnormal termination, perform the following steps:
- Remove the lock file.
Type the following command: rm -f /var/lock/.spsetup
- Run the Update Package again to reapply the update.
* Do not run storage controller update packages if the controller is in use by other applications.
The firmware upgrade may fail if any of the RAID controllers in the system are performing an I/O background task (that is, consistency check, background initialization, rebuild, or reconstruction). Allow the background task to complete before attempting to upgrade the firmware. Patrol Read tasks will not affect a firmware upgrade.
* Linux systems running one or more applications that interact with SCSI devices in certain ways are known to cause a kernel panic situation. Therefore, it is recommended that you stop Server Administrator and its Storage Management Service before running storage controller firmware update packages.
To stop the Dell OpenManage(TM) Server Administrator service, run "omconfig system webserver action=stop"
To start the Server Administrator service, run "omconfig system webserver action=start"
To stop the Server Administrator Storage Management Service, run "/etc/init.d/dataeng stop"
To start the Server Administrator Storage Management Service, run "/etc/init.d/dataeng start"
Supported Operating Systems
Installation instructions
Update to latest available system firmware for iDRAC, BIOS, and CPLD from respective System drivers and downloads support site before updating PERC.
If updating from FW package 52.16.1-4158 (or older) an AC or Virtual AC cycle of the system is required.
Note: When a Virtual AC cycle is performed, the iDRAC controller will be reset and be unavailable for a short time (approx: 2 minutes)
Performing the Firmware Upgrade
===================================
Windows Update Package:
Download
1. From http://www.dell.com/support/home, download the update package and save it to your local hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
Linux Update Package:
Download
1. From http://www.dell.com/support/home, download the update package and save it to your local hard drive.
Installation
1. Read over the release information presented by executing the
"./SAS-RAID_Firmware_1DHXW_LN64_52.30.0-6347_A05.BIN --version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Run the update by executing "./SAS-RAID_Firmware_1DHXW_LN64_52.30.0-6347_A05.BIN" from the shell.
4. Follow the remaining prompts to perform the update.
IDRAC/LC
1. Download the Windows DUP Executable from http://www.dell.com/support/home
2. Upload DUP to IDRAC or LC
3. Submit job and reboot the system
VMware/PERCcli
1. Download the DUP from http://www.dell.com/support/home to a local system
2. Extract the Payload files from the DUP
Extracted DUP > Common > Payload
3. Download and install the latest PERCCLI version to your server if not already installed
4. Copy the DUP payload files to your server
5. Navigate to PERCCLI folder
Windows - folder with perccli.exe
Linux - /opt/Megaraid/perccli
VMware - /opt/lsi/perccli
Note that PERCcli requires administrator privileges to run
6. Install the Firmware to your controller with the below command
perccli /c download file= \Path To\.rom
7. Reboot the system
Applies to
INFO,H355,LK,FW,52.30.0-6347
PERC H355 Adapter
PERC H355 Front