DELL PERC H700 Integrated firmware release 12.10.7-0001

재시작 필요
DELL PERC H700 Integrated firmware release 12.10.7-0001

최신 드라이버 다운로드

이 드라이버의 업데이트 버전이 있을 수 있습니다.

이 드라이버는 최신 상태임

드라이버 정보가 최신 상태입니다. PowerEdge R910의 드라이버를 모두 보려면 드라이버 및 다운로드로 이동하십시오.

수정 또는 개선한 내용

Fixes
- Fixes an issue where a server with the following storage conditions can cause the controller to become offline:
1. Affected Raid levels are R5, R6, R50, and R60
2. The stripe size of the virtual disk and the size of the virtual disk meet any of the following conditions:
Stripe Size Virtual Drive Size
8K >35TB
16K >70TB
32K >140TB
64K >281TB
128K >562TB
256K >1125TB
If you meet all of these criteria then the update is critical, otherwise update at your convenience.

Enhancements
- Not Applicable

버전

버전 12.10.7-0001, A13

범주

SAS RAID

출시일

04 9월 2015

최종 업데이트

04 11월 2016

중요도

사용 가능한 형식

파일 형식: Update Package for Microsoft® Windows® 64-Bit.
파일 이름: SAS-RAID_Firmware_9FVJ2_WN64_12.10.7-0001_A13.EXE
다운로드 유형: HTTP
파일 크기: 15.45 MB
형식 설명:
기본 Microsoft Windows 64비트 형식의 Dell 업데이트 패키지를 사용하기 위해 Microsoft Windows Server에 Microsoft WOW64를 설치할 필요는 없습니다. 
To ensure the integrity of your download, please verify the checksum value.
MD5:
cc209fb5f83129a737a0ff80d5b34cae
SHA1:
703c22b596b9977da52c36f5a8a96f9665546584
SHA-256:
431412cda6e9a8edc79ed7a5dbd203fe2c6e5b01317676640ececcf054cd8959
파일 형식: Rel-Notes-Text
파일 이름: SAS_RAID_Firmware_H700I_RELNOTES_12.10.7-0001_A13.txt
다운로드 유형: HTTP
파일 크기: 13.74 KB
형식 설명:
이 파일 포맷은 표준 텍스트 편집기를 사용하여 볼 수 있는 일반 텍스트를 포함합니다.
To ensure the integrity of your download, please verify the checksum value.
MD5:
ea35d0e1781c4c2dfe3d5ee28b1212dc
SHA1:
ef17a53cfa519374a6946f4ce3e842bb95151195
SHA-256:
9fc09c573219bc367f53285bddf8981da5b48cb73fb2fbd571004f11c5f531e1

다운로드할 경우 Dell 소프트웨어 라이센스 계약 (영어로) 에 동의하는 것으로 간주합니다.

12.10.6-0001, A12 22 7월 2013
12.10.4-0001, A10 08 5월 2012
12.10.3-0001, A09 08 3월 2012
PERC H700 Integrated
Performing the Firmware Upgrade

NOTE: This initial section of the Installation Instructions applies only to configurations with (greater than) 2TB SEDs.

1. Update the firmware version to this version using preferred method below (Windows DUP, Linux DUP, or PERCCLI).
2. Reboot for the new FW take effect
3. Un-assign any (greater than) 2TB SED Dedicated or Global Hot Spares in the configuration. Not all configurations have hot spares.
4. Use CTRL-R or OMSS to issue Instant Secure Erase to all un-configured (greater than) 2TB SED drives (all data in these drives will be lost)
5. Re-assign (greater than) 2TB SED Hot Spares.


Windows Update Package:

Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click Save to save the file to
your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window
before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.


Linux Update Package:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Read over the release information presented by executing the
./FRMW_LX_RXXXXXX.BIN --version command from the shell.
2. Download and install any prerequisites identified in the above step before
proceeding.
3. Run the update by executing ./FRMW_LX_RXXXXXX.BIN from the shell.
4. Follow the remaining prompts to perform the update.

GnuPG Signature of Dell Update Package Instructions for FRMW_LX_RXXXXXX.BIN:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to do this once on your system.)
2. Verify the Dell Update Package by using its signature file, FRMW_LX_RXXXXXX.BIN.


PERCCLI Install:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Click the Extract button and extract the Dell Update Package to a folder of your choice.
3. Download the PERCCLI utility for your respective operating system from support.dell.com (www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3XDPP).
4. Install PERCCLI.
5. Open a command line prompt.
6. Run 'perccli show' and make note of the controller number for the controller you wish to update. If you only have one PERC in the system it will be controller 0.
7. Run 'perccli /cx download file=' where x=the index number for the controller you got in step 6.
8. Reboot the server as directed once the firmware flash completes.

드라이버 도움말 및 자습서