DELL PERC H700 Integrated firmware release 12.10.7-0001

需要重新启动 已自动安装 此文件是作为最近更新的一部分自动安装的。如果您遇到任何问题,您可以手动下载并重新安装。
此页面的内容可能已自动翻译。要提供反馈,请填写页面底部的表单。
DELL PERC H700 Integrated firmware release 12.10.7-0001
推荐

查找适合您的系统的最佳下载内容

请输入您的产品详细信息以查看系统的最新驱动程序信息

搜索支持

输入您的戴尔服务编号或型号

想要查找您的产品吗?请输入产品标识符。 演示操作

此驱动程序不兼容

此驱动程序不适用于所选产品。选择另一个产品以重新输入此驱动程序的产品详细信息,或访问产品支持页面以查看其他产品的所有驱动程序。

补丁和增强功能

Fixes
- Fixes an issue where a server with the following storage conditions can cause the controller to become offline:
1. Affected Raid levels are R5, R6, R50, and R60
2. The stripe size of the virtual disk and the size of the virtual disk meet any of the following conditions:
Stripe Size Virtual Drive Size
8K >35TB
16K >70TB
32K >140TB
64K >281TB
128K >562TB
256K >1125TB
If you meet all of these criteria then the update is critical, otherwise update at your convenience.

Enhancements
- Not Applicable
了解详情

版本

12.10.7-0001, A13

发布日期

04 9月 2015

下载类型

固件

类别

SAS RAID

重要性

紧急
Dell Technologies 强烈建议尽快应用这一重要更新。更新包含重要的错误修复和更改,以提高戴尔系统的功能、可靠性和稳定性。它还可能包括安全修复和其他功能增强功能。
可用格式

文件格式: MS Windows(64位)的更新包。
文件名: SAS-RAID_Firmware_9FVJ2_WN64_12.10.7-0001_A13.EXE
文件大小: 15.45 MB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
如戴尔更新包为原生微软64位格式,则不需要在微软Windows服务器上安装WOW64。
为确保下载的完整性,请验证校验和值。
MD5:
cc209fb5f83129a737a0ff80d5b34cae
SHA1:
703c22b596b9977da52c36f5a8a96f9665546584
SHA-256:
431412cda6e9a8edc79ed7a5dbd203fe2c6e5b01317676640ececcf054cd8959

文件格式: 包含加密签名的GnuPG文件
文件名: SAS-RAID_Firmware_9FVJ2_LN_12.10.7-0001_A13.BIN.sign
文件大小: 194 Bytes
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
Red Hat Linux更新包的GnuPG签名可用于验证戴尔在相关Red Hat Linux更新包中的身份。
为确保下载的完整性,请验证校验和值。
MD5:
64f2c1fb55b017c023af12300b0ad37c
SHA1:
242b6a8b7a5e0410592ecfba9849ad0e729bd8db
SHA-256:
a632923ee6aaee724caec05234ef04b730e310a61a7268a0522e91e01f1726a7

文件格式: 外部版本说明
文件名: SAS_RAID_Firmware_H700I_RELNOTES_12.10.7-0001_A13.txt
文件大小: 13.74 KB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
此文件格式包含纯文本,您可以采用标准文本编辑器进行查看。
为确保下载的完整性,请验证校验和值。
MD5:
ea35d0e1781c4c2dfe3d5ee28b1212dc
SHA1:
ef17a53cfa519374a6946f4ce3e842bb95151195
SHA-256:
9fc09c573219bc367f53285bddf8981da5b48cb73fb2fbd571004f11c5f531e1

文件格式: 面向MS Windows(32位)的更新包
文件名: SAS-RAID_Firmware_9FVJ2_WN32_12.10.7-0001_A13.EXE
文件大小: 10.1 MB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
Microsoft Windows 32位格式中的戴尔更新包(DUP)设计为可以在Microsoft Windows 64位操作系统上运行。Microsoft Windows 64位格式中的戴尔更新包(DUP)仅可在Microsoft Windows 64位操作系统上运行。选择设备驱动程序更新时,请务必选择适合您的操作系统的更新。
为确保下载的完整性,请验证校验和值。
MD5:
4219846641ced28db06a5b22f6431816
SHA1:
27ad65e00c1affa39215c7d68e089b96c928a030
SHA-256:
2a55fddd50b36e1ab02b7c6bc1d5637eed2232ba5878825d9c94c04ae75e204f

文件格式: Red Hat Linux的更新包
文件名: SAS-RAID_Firmware_9FVJ2_LN_12.10.7-0001_A13.BIN
文件大小: 39.92 MB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
适用于Linux 的戴 尔更新包是在 满足特定的标准系统环境下使用的独立应用程序。,然后应用更新。
注意:Linux的更新包是开源的。查看适用于Linux 的戴 尔更新包自述以了解 详情,了解详情。
为确保下载的完整性,请验证校验和值。
MD5:
5eaa68ebc93e9112cb31a72d4e35aba1
SHA1:
6382887178c1031f0bc9c19b9956de16cdb4c370
SHA-256:
adc2591d15981cf64655fd5b1eb96f05196e25eae8c70f7667268337b1e5307a

开始下载软件,即表示您接受戴尔软件许可协议 ( 英文版 ) 条款。

PERC H700 Integrated
Performing the Firmware Upgrade

NOTE: This initial section of the Installation Instructions applies only to configurations with (greater than) 2TB SEDs.

1. Update the firmware version to this version using preferred method below (Windows DUP, Linux DUP, or PERCCLI).
2. Reboot for the new FW take effect
3. Un-assign any (greater than) 2TB SED Dedicated or Global Hot Spares in the configuration. Not all configurations have hot spares.
4. Use CTRL-R or OMSS to issue Instant Secure Erase to all un-configured (greater than) 2TB SED drives (all data in these drives will be lost)
5. Re-assign (greater than) 2TB SED Hot Spares.


Windows Update Package:

Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click Save to save the file to
your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window
before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.


Linux Update Package:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Read over the release information presented by executing the
./FRMW_LX_RXXXXXX.BIN --version command from the shell.
2. Download and install any prerequisites identified in the above step before
proceeding.
3. Run the update by executing ./FRMW_LX_RXXXXXX.BIN from the shell.
4. Follow the remaining prompts to perform the update.

GnuPG Signature of Dell Update Package Instructions for FRMW_LX_RXXXXXX.BIN:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to do this once on your system.)
2. Verify the Dell Update Package by using its signature file, FRMW_LX_RXXXXXX.BIN.


PERCCLI Install:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Click the Extract button and extract the Dell Update Package to a folder of your choice.
3. Download the PERCCLI utility for your respective operating system from support.dell.com (www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3XDPP).
4. Install PERCCLI.
5. Open a command line prompt.
6. Run 'perccli show' and make note of the controller number for the controller you wish to update. If you only have one PERC in the system it will be controller 0.
7. Run 'perccli /cx download file=' where x=the index number for the controller you got in step 6.
8. Reboot the server as directed once the firmware flash completes.

驱动程序帮助和教程