請勿在更新 BIOS 時將電腦關機或拔除電源,電腦可能因此受損。更新期間,電腦將重新啟動,並且會暫時顯示黑色畫面。

更新前,請閱讀以下所述的安裝說明與重要資訊。

Dell EMC Server BIOS PowerEdge T640 Version 1.3.7

需要重新啟動 已自動安裝 此檔案會在最近更新時自動安裝。如果您遇到任何問題,可以手動下載並重新安裝。
此頁面的內容可能經過電腦自動翻譯。若要提供意見回饋,請填寫頁面底部的表單。
This release contains new Intel Xeon Processor Scalable Family Processor Microcode to address CVE-2017-5715.
CVE-2017-5753 and CVE-2017-5754 do not require a microcode update.
This release fixes Intel Management Engine issue that causes first BIOS flash update attempt to fail after 24 days of server up-time.
This release contains BIOS firmware version 1.3.7 for Dell EMC Server PowerEdge T640.
建議

為您的系統尋找最適合的下載項目

請輸入產品的詳細資料以檢視系統的最新驅動程式資訊

搜尋支援

輸入您的 Dell 產品服務編號或型號

想要尋找您的產品嗎?請輸入產品識別碼。 告訴我怎麼做

此驅動程式不相容

此驅動程式不適用於選取的產品。請選擇其他產品,以重新輸入適用於此驅動程式的產品詳細資料,或前往產品支援頁面,檢視其他產品的所有驅動程式。

尋找更多更新。使用 SupportAssist 為您的裝置尋找所有最新的驅動程式更新。

修復及強化

Fixes:
* BIOS takes a long time to handle correctable memory errors.
* Rarely, the system may stop at POST (Power-On-Self-Test) when running reboot test in the BIOS boot mode.
* Several NVMe-related defects are resolved.
* Intel Management Engine issue that causes first BIOS flash update attempt to fail after 24 days of server up-time.
- Fix does not take effect until after flashing this BIOS.
- See PSQN SLN309027 for complete detail - http://www.dell.com/support/article/us/en/04/SLN309027

Enhancements:
* Added NVDIMM-N Namespace support for the VMWare ESXi 6.7 version.
* Updated the Intel Trusted Execution Technology (Intel TXT) BIOS Authenticated Code Module (ACM) to version 1.3.4.
* Updated the Intel Processor and Memory Reference Code to PLR3.1.
* To address CVE-2017-5715 (http://www.cve.mitre.org/cgi-bin/cvename.cgi?name=2017-5715).
- Updated the Intel Xeon Processor Scalable Family Processor Microcode to version 0x43.
- CVE-2017-5753 and CVE-2017-5754 are addressed by Operating System & Hypervisor updates.
- For more information, visit http://www.dell.com/support/article/SLN308588
閱讀更多

繁體中文版

1.3.7, 1.3.7

發佈日期

18 2月 2018

下載類型

系統 BIOS

類別

BIOS

重要性

緊急
Dell Technologies 強烈建議儘快套用此重要更新。此更新包含的重大錯誤修正和變更,可改善 Dell 系統功能、可靠性及穩定性。其也可能包含安全性修正和其他增強功能。
可用的格式 檢視重要資訊

檔案格式: 適用於 MS Windows (64 位元) 的更新套件。
檔案名稱: BIOS_P3V6F_WN64_1.3.7.EXE
檔案大小: 26.25 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
如果 Dell 更新套件為原生 Microsoft Windows 64 位元格式,則不需要在 Microsoft Windows Server 安裝 Microsoft WOW64。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
f5a359904e0f1d41e27c201c0ef6741a
SHA1:
46bf268b6d13e3c71638acfd0652e4a4bd1eb048
SHA-256:
06e88cd9aaadd1c7c541f53ac9b95c806287e6ec53f06b5521b4bdb8211225f4

檔案格式: 包含密碼編譯簽章的 GnuPG 檔案
檔案名稱: BIOS_P3V6F_LN_1.3.7.BIN.sign
檔案大小: 226 Bytes
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
您可以使用適用於 Red Hat Linux 更新套件的 GnuPG 簽章,在相關聯的 Red Hat Linux 更新套件中驗證 Dell 的身分。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
76eb910e15fb56d71af72616cb422f24
SHA1:
d2ee5dd0f858bc5c5b7b31b5f0b7eacb5eb41164
SHA-256:
0c54d7ef2f999eda09e209d7cb2ac5010b77535eaf77414ce1747fb167523356

檔案格式: 適用於 64 位元機器的自動解壓縮檔案
檔案名稱: T640-010307.efi
檔案大小: 17.92 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
此檔案內含可從 EFI Shell 或 EFI Boot Manager執行的壓縮內容。將檔案下載到抽取式媒體裝置的 EFI 分割區。插入抽取式媒體,然後將系統重新開機,並透過 EFI Shell 或 EFI Boot Manager 執行程式。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
61ea109f61b87a73c24577a0e90be76f
SHA1:
7456612a507220c2f7c4d4ed339475b4b8f31195
SHA-256:
2d552b307e4a9f318058a2d6d56d28dbe774cb7859cbba9330630f3dd036c336

檔案格式: 封存的 PDF 檔案提供客戶說明及程序資訊
檔案名稱: T640_BIOS.1.3.7_RN.pdf
檔案大小: 209.84 KB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
此格式包含 PDF 檔案的封存,可用來向客戶提供說明及程序性資訊。請務必先安裝 Adobe Acrobat Reader 以檢視此封存中的檔案。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
aec91718bcacb0f88fdaa8664926a325
SHA1:
e7c113f2bfb5c07ff741cb2bfd5472c4f070afcd
SHA-256:
fee5094e8fe24a1edccda1624925717aef1066ab5203e72d39b8e80679fb6ec0

檔案格式: 適用於 Red Hat Linux 的更新套件
檔案名稱: BIOS_P3V6F_LN_1.3.7.BIN
檔案大小: 26.61 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
適用於 Linux 的 Dell 更新套件可做為獨立的應用程式,確保符合特定的驗證條件,然後套用更新。
注意:適用於 Linux 的更新套件為開放原始碼套件。請參閱適用於 Linux 的 Dell 更新套件的「讀我」檔案,瞭解詳情。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
962f822c1fdb9421d826b12bf091b9cd
SHA1:
7b914b2b3acbd81d3879edd3a6c54bc85e157350
SHA-256:
ffb8b935e3a79727afa8447edbe2101a328866e60d1e26f1397408fc94c64abb

當您開始下載,即表示您接受 Dell 軟體授權協定 (英文版) 的條款。

其他詳細資料

顯示全部 | 隱藏全部
An Intel Management Engine related issue that caused the BIOS update to fail is resolved in this BIOS 1.3.7 version.
- This included remedy becomes effective only after the device is updated with this BIOS 1.3.7 version.
Warning: Running an iDRAC RACADM power cycle command while running an operating system causes an ungraceful shutdown.
- To work around this issue, AC power cycle the system or run the iDRAC RACADM power cycle command before updating the BIOS.
- The first attempt to upgrade to this 1.3.7 version will fail, but the second attempt will pass if done within 24 days after the first attempt.
- For more information about this issue and safely working around this issue, see:
PSQN SLN 309027 here: http://www.dell.com/support/article/us/en/04/SLN309027
Intel HSD125807 here:
https://www.intel.com/content/dam/www/program/design/us/en/documents/hsd125807-hmrfpo-timeout-ta-337128.pdf?asset=16254
INFO,BIOS LOCK,T640XL,Q1FY19
T640 BIOS
Dell EMC Update Package Instructions for EFI
Download
1. Click the "Download Now" link to download the file.
2. If the Export Compliance Disclaimer window appears, click the "I agree" link if you accept the agreement.
3. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
You can update the BIOS using a UEFI shell bootable media, such as a USB key.
1. Copy the file to the bootable device with UEFI shell.
2. Boot the system to UEFI shell by using the bootable device.
3. Run the executable (.efi) under the UEFI shell. Follow the instructions provided by the flash utility.

You can also load this executable directly from BIOS Boot Manager without a UEFI shell bootable media.
1. Copy the file to a USB device
2. Plug in the USB device and press F11 during POST to enter BIOS Boot Manager
3. Navigate to the System Utilities menu and select BIOS Update File Explorer
4. Select the USB device and navigate through the directory contents to find the executable (.efi)
5. Launch the executable and follow the instructions provided by the flash utility.
--------------------------------------------------------------------------------
Dell EMC Update Package Instructions for Linux DUP:
Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Read over the release information presented by executing the "./[model]_BIOS_LX_[revision].BIN --version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Install any necessary Embedded Systems Management firmware prior to this BIOS update.
4. Run the update by executing "./[model]_BIOS_LX_[version].BIN" from the shell.
5. Follow the remaining prompts to perform the update.
-----------------------------------------------------
Dell EMC Update Package Instructions for Windows Dup:
Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Install any necessary Embedded Systems Management firmware prior to this BIOS update.
5. Click the Install button.
6. Follow the remaining prompts to perform the update.
-----------------------------------------------------
GnuPG Signature of Dell EMC Update Package Instructions:
Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.
Installation
1. Import the Dell EMC public key. (You only need to do once on your system.)
2. Verify the Dell EMC Update Package by using its signature file, [model]_BIOS_LX_[version].BIN.sign

需要 BIOS 問題的協助嗎?

請在 Dell 的 BIOS 故障診斷和使用指南中尋找解決方案。

驅動程式說明與教學課程