ECS: Migrated Clip cannot be read - Error Code: Maximum C-Clip size reached
Zusammenfassung: Unable to read clip that has been migrated from Centera to ECS due to error Maximum Clip Size
Dieser Artikel gilt für
Dieser Artikel gilt nicht für
Dieser Artikel ist nicht an ein bestimmtes Produkt gebunden.
In diesem Artikel werden nicht alle Produktversionen aufgeführt.
Symptome
CAS migration from Centera to ECS
Clip that has been migrated from Centera to ECS cannot be read and throws error: Maximum C-Clip size reached, code: -10026
Example of the failed restore on ECS:
Clip that has been migrated from Centera to ECS cannot be read and throws error: Maximum C-Clip size reached, code: -10026
Example of the failed restore on ECS:
java -jar /home/filepool/bin/CenteraExerciser.jar -address xx.xx.xx.xx?casuser.pea -order ro -clipfile file Starting restore of clips and blobs to cluster... FPClip::CheckCDFSizeEstimate()<FPTag::BlobWrite(stream,2)<FPTag_BlobWrite(-,-,0) com.filepool.fplibrary.FPLibraryException: Maximum C-Clip size reached at com.filepool.fplibrary.FPTag.BlobWrite(Unknown Source) at com.filepool.fplibrary.FPTag.BlobWrite(Unknown Source) at com.emc.centera.apiengine.core.CenteraSDK.storeRAW(CenteraSDK.java:2150) at com.emc.centera.centeraexerciser.utils.RawOpenThread.run(RawOpenThread.java:215) ERROR: Writing blob (com.filepool.fplibrary.FPTag@1cd296b.BlobWrite(java.io.FileInputStream@5a7159)) - com.filepool.fplibrary.FPLibraryException: Maximum C-Clip size reached, code: -10026 [Thread-1] CenteraSDK.java:2169 at 2019-05-07 17:41:06,757 **** RawOpen(s) finished **** Test has finished with 1 errors Test failed
Ursache
Centera cannot migrate clips over 100 MB to the ECS.
This is by design, it is CAS SDK behavior which stops taking additional tags once CDF crosses 100 MB. Although a raw-read is successful on the Centera, the file read on ECS fails.
This is by design, it is CAS SDK behavior which stops taking additional tags once CDF crosses 100 MB. Although a raw-read is successful on the Centera, the file read on ECS fails.
Lösung
The clip must be directly written from the application to the Centera and then migrated once more to ECS. This generates a new clip ID.
The new clip must be updated on customer application database. It may have to be stored with previous clip ID which can cause read errors.
The new clip must be updated on customer application database. It may have to be stored with previous clip ID which can cause read errors.
Betroffene Produkte
ECS ApplianceProdukte
ECS ApplianceArtikeleigenschaften
Artikelnummer: 000050451
Artikeltyp: Solution
Zuletzt geändert: 22 Feb. 2023
Version: 3
Antworten auf Ihre Fragen erhalten Sie von anderen Dell NutzerInnen
Support Services
Prüfen Sie, ob Ihr Gerät durch Support Services abgedeckt ist.