VxRail: SSD Write Endurance Below Threshold Event VXR508SSD0001
Résumé: The VXR508SSD0001 event indicates a solid‑state drive’s remaining write‑rated endurance is below its threshold, causing a yellow alarm in the vCenter portal and possibly a false‑positive alert. ...
Cet article concerne
Cet article ne concerne pas
Cet article n’est associé à aucun produit spécifique.
Toutes les versions du produit ne sont pas identifiées dans cet article.
Symptômes
iDRAC event SSD0001 occurs and YELLOW alarm VXR508SSD0001 present in the vCenter portal.
Cause
The Write Endurance of solid state drive identified in the message is less than the threshold value of Remaining Write Rated Endurance.
Résolution
To confirm if this test is a false positive or not:
- Collect a support assist log, also called TSR, for the node. See: PowerEdge: Export a SupportAssist Collection Using iDRAC UI or racadm cmd
- Clear system event log, see: PowerEdge: How to View or Clear the System event log
- Reset the iDRAC, see: PowerEdge: How to Reset the Integrated Dell Remote Access Controller (iDRAC)
Performing an iDRAC reset forces the iDRAC to reinventory the controller and disk health status. Wait 5-10 minutes after the reset and check the remaining disk endurance from the physical disk page. If the error persists, contact support and provide the TSR collected in step 1: Contact Technical Support | Dell US
Note: If the event code "
VXR508SSD0001: Write Endurance of SSD is below the threshold value" is observed, it may be identified as a false positive alert and can be safely ignored.
Produits concernés
VxRail, VxRail D560F, VxRail E560F, VxRail E660F, VxRail E665F, VxRail G560F, VxRail P570F, VxRail P670F, VxRail P675F, VxRail V570F, VXRAIL V670FPropriétés de l’article
Numéro d’article: 000184532
Type d’article: Solution
Dernière modification: 25 juin 2026
Version: 10
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support
Vérifiez si votre appareil est couvert par les services de support.