VPLEX: Sådan får du vist CPU-kerneforbruget på en VPLEX-director

Summary: Denne KB-artikel viser, hvordan du får vist det aktuelle kerne-CPU-forbrug på en bestemt VPLEX-director.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

  1. Fra administrationsserveren skal du logge ind på direktøren direkte ved hjælp af følgende kommando: service@mgmtserver~> ssh service@128.221.252.35
  2. Kør top Kommando til visning af kørende proces:
    service@director-1-1-a:~> top

  3. Tryk på tallet '1' for at se CPU-kerneforbruget på direktøren:
Eksempel på output:

Director-1-1-A
Cpu0 :  6.9%us, 19.3%sy, 0.0%ni, 73.7%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
Cpu1 : 62.9%us, 18.7%sy, 0.0%ni, 18.4%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
Cpu2: 47,0%us, 27,4%sy, 0,0%ni, 25,7%id, 0,0%wa, 0,0%hi, 0,0%si, 0,0%st
CPU3 :  1.0%us, 0.0%sy, 0.0%ni, 99.0%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
Cpu4 :  2.0%us, 7.8%sy, 0.0%ni, 90.1%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
Cpu5 :  0.3%us, 1.0%sy, 0.0%ni, 98.7%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
CPU6 :  0.3%us, 0.0%sy, 0.0%ni, 99.7%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
Cpu7 :  1.3%us, 0.3%sy, 0.0%ni, 98.0%id, 0.0%wa, 0.0%hi, 0.3%si, 0.0%st

Director-1-1-B
==============
Cpu0:  1.6%us, 2.3%sy, 0.0%ni, 95.9%id, 0.0%wa, 0.0%hi, 0.2%si, 0.0%st
CPU1 :  1.8%us, 0.7%sy, 0.0%ni, 97.4%id, 0.0%wa, 0.0%hi, 0.1%si, 0.0%st
Cpu2:  0.4%us, 0.2%sy, 0.0%ni, 99.4%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
CPU3:  0.3%us, 0.1%sy, 0.0%ni, 99.5%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
Cpu4 :  0.2%us, 0.1%sy, 0.0%ni, 99.7%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
Cpu5 :  0.4%us, 0.2%sy, 0.0%ni, 99.4%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
CPU6:  0.4%us, 0.2%sy, 0.0%ni, 99.4%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
CPU7 :  0.1%us, 0.1%sy, 0.0%ni, 99.8%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st

Director-1-2-A
==============
Cpu0:  6.8%us, 21.5%sy, 0.0%ni, 71.5%id, 0.0%wa, 0.0%hi, 0.2%si, 0.0%st
Cpu1 : 76,8%us, 15,7%sy, 0,0%ni, 7,6%id, 0,0%wa, 0,0%hi, 0,0%si, 0,0%st
CPU2: 54,3%us, 22,3%sy, 0,0%ni, 23,5%id, 0,0%wa, 0,0%hi, 0,0%si, 0,0%st
CPU3 :  1.3%us, 0.8%sy, 0.0%ni, 97.8%id, 0.0%wa, 0.0%hi, 0.1%si, 0.0%st
CPU4:  3.4%us, 8.6%sy, 0.0%ni, 87.8%id, 0.0%wa, 0.0%hi, 0.1%si, 0.0%st
Cpu5 :  0.4%us, 0.4%sy, 0.0%ni, 99.2%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
CPU6:  0.4%us, 0.2%sy, 0.0%ni, 99.3%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
CPU7:  1.3%us, 0.8%sy, 0.0%ni, 97.7%id, 0.0%wa, 0.0%hi, 0.1%si, 0.0%st

Director-1-2-B
==============
Cpu0:  6.0%us, 19.1%sy, 0.0%ni, 74.5%id, 0.0%wa, 0.0%hi, 0.4%si, 0.0%st
Cpu1 : 73,4%us, 18,4%sy, 0,0%ni, 8,2%id, 0,0%wa, 0,0%hi, 0,0%si, 0,0%st
CPU2: 53,0%us, 22,3%sy, 0,0%ni, 24,7%id, 0,0%wa, 0,0%hi, 0,0%si, 0,0%st
CPU3:  1.0%us, 0.7%sy, 0.0%ni, 98.3%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
Cpu4 :  4.7%us, 8.1%sy, 0.0%ni, 86.8%id, 0.0%wa, 0.0%hi, 0.3%si, 0.0%st
Cpu5 :  0.0%us, 0.0%sy, 0.0%ni,100.0%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
Cpu6 :  0.3%us, 0.0%sy, 0.0%ni, 99.7%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
Cpu7 :  0,3%US, 0,3%SY, 0,0%NI, 99,3%ID, 0,0%WA, 0,0%HI, 0,0%SI, 0,0%ST

Additional Information

CLUSTER-1 IP-adresser
Motor 1 Direktør 1-1-A A 128.221.252.35 B 128.221.253.35
          Direktør 1-1-B A 128.221.252.36 B 128.221.253.36
Motor 2 Direktør 1-2-A A 128.221.252.37 B 128.221.253.37
Direktør 1-2-B A 128.221.252.38 B 128.221.253.38
Motor 3 Direktør 1-3-A A 128.221.252.39 B 128.221.253.39
Direktør 1-3-B A 128.221.252.40 B 128.221.253.40
Maskine 4 Direktør 1-4-A A 128.221.252.41 B 128.221.253.41
Direktør 1-4-B A 128.221.252.42 B 128.221.253.42

                                                                 
CLUSTER-2 IP-adresser
Maskine 1 Direktør 2-1-A A 128.221.252.67 B 128.221.253.67
Direktør 2-1-B A 128.221.252.68 B 128.221.253.68
Maskine 2 Direktør 2-2-A A 128.221.252.69 B 128.221.253.69
Direktør 2-2-B A 128.221.252.70 B 128.221.253.70
Maskine 3 Direktør 2-3-A A 128.221.252.71 B 128.221.253.71
Direktør 2-3-B A 128.221.252.72 B 128.221.253.72
Motor 4 Direktør 2-4-A A 128.221.252.73 B 128.221.253.73
Direktør 2-4-B A 128.221.252.74 B 128.221.253.74