VPLEX: 0x8a2d30aa - Dial-home - An array returned Unit Attention 6/38/07h THIN_PROVISIONING_SOFT_THRESHOLD_REACHED.

Summary: This article provides a description of the thin provisioning soft threshold dial-home and recommendations to resolve the warning.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

A change in thin pool utilization on the back-end storage array behind VPLEX.

VPLEX dials home reporting the following message:
<Event>
  <SymptomCode>0x8a2d30aa</SymptomCode>
  <Category>Status</Category>
  <Severity>Warning</Severity>
  <Status>Warning</Status>
  <Component>CLUSTER</Component>
  <ComponentID>director-2-1-B</ComponentID>
  <SubComponent>scsi</SubComponent>
  <SubComponentID></SubComponentID>
  <CallHome>Yes</CallHome>
  <FirstTime><Date and timestamp>Z</FirstTime>
  <LastTime><Date and timestamp>Z</LastTime>
  <Count>4</Count> << this value will vary
<EventData><![CDATA[Thin Provisioning Soft Threshold reached - vol VPD83T3:6006016007f03e0048886ea54138e811  [Versions:MS{Dx.x.x.x.x, Dx.x.x.x, Dx.x.x.x}, Director{x.x.x.x.x}, ClusterWitnessServer{Dx.x.x.x}] RCA: An array returned Unit Attention 6/38/07h THIN_PROVISIONING_SOFT_THRESHOLD_REACHED for a storage-volume on a VPLEX write. The thin pool on the array is running out of space. Remedy: Add additional block resources to the thin pool on the array from which the storage-volume is provisioned.
]]></EventData>
  <Description><![CDATA[A storage volume reported a Thin Provisioning Soft Threshold Reached error on a VPLEX write.

 

Cause

When VPLEX sends a SCSI write command from the host to a thin storage-volume provisioned from a thin pool that is over the pre-configured soft threshold for utilization, the storage array may return a unit attention 6/38/07h alert to the VPLEX signaling that the storage pool is running low on space.

A unit attention is a sense key which a storage array can use to communicate a change in its operational state to other devices (such as the VPLEX). When VPLEX receives this unit attention alert it will report this notice on behalf of the array in a dial-home with tas a warning with the symptom code ID 0x8a2d30aa. This dial-home does not indicate an issue with the VPLEX, instead it indicates a threshold surpassed on an array behind the VPLEX. VPLEX is just reporting the symptom.
 

Resolution

To resolve this issue, have the Storage Admin either add additional block resources to the thin pool on the back-end array reporting the issue or increase the soft threshold (if supported by the array) to a value greater than the current utilization.

Additional Information

To identify the array and storage-volume returning the unit attention find the VPD for the volume in the CDATA portion of the dial home message.

Thin Provisioning Soft Threshold reached - vol VPD83T3:60060160c9c02c00520c47ef8ac4e711 <-- Volume reporting the issue
[Versions:MS{Dx.x.x.x.x, Dx.x.x.x, Dx.x.x.x}, Director{x.x.x.x.x}, ClusterWitnessServer{unknown}] RCA: An array returned Unit Attention 6/38/07h THIN_PROVISIONING_SOFT_THRESHOLD_REACHED for a storage-volume on a VPLEX write. The thin pool on the array is running out of space. Remedy: Add additional block resources to the thin pool on the array from which the storage-volume is provisioned.

From the VPLEX CLI run the command 'show-use-hierarchy /clusters/*/storage-elements/storage-arrays/*/logical-units/<Volume ID>' to list out the details of the storage volume.

VPlexcli:/> show-use-hierarchy /clusters/*/storage-elements/storage-arrays/*/logical-units/VPD83T3:60060160c9c02c00520c47ef8ac4e711
storage-view: test_view (cluster-1)
  consistency-group: CGTEST_100 (synchronous)
    virtual-volume: Device-C1-1_1_1_vol (10G, local @ cluster-1, running)
      local-device: Device-C1-1_1 (10G, raid-0, cluster-1)
        extent: extent_CLARiiON1539_LUN_C1-4006-1_1 (10G)
          storage-volume: CLARiiON1539_LUN_C1-4006-1 (10G)
            logical-unit: VPD83T3:60060160c9c02c00520c47ef8ac4e711
              storage-array: EMC-CLARiiON-APMxxxxxxxxxxx <-- Array where the volume is located

Affected Products

VPLEX, VPLEX GeoSynchrony

Products

VPLEX VS2, VPLEX VS6
Article Properties
Article Number: 000170715
Article Type: Solution
Last Modified: 23 ديسمبر 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.