PowerFlex SDS 在 SDBG 伺服器啟動時發生錯誤
Summary: SDS 無法啟動。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
案例
SDS 解耦,在嘗試啟動時,它會重複當機,其中疑似問題出在 SDBG 伺服器啟動。
症狀
在啟動嘗試堆疊追蹤時重複錯誤:
08/03 20:56:58.388914 Panic in file /data/build/workspace/ScaleIO-Common-Job/src/tgt/tgt.c, line 303, function main, PID 50379.Panic Expression rc== 65 PANIC_ID_tgt_1511773103687. /opt/emc/scaleio/sds/bin/sds-3.5.1100.107(mosDbg_PanicPrepare+0x13a) [0x93b62a] /opt/emc/scaleio/sds/bin/sds-3.5.1100.107(main+0x2ce) [0x4cd18e] /lib64/libc.so.6(__libc_start_main+0xf5) [0x7fb153287555] (...) 08/03 21:13:59.562976 Panic in file /data/build/workspace/ScaleIO-Common-Job/src/tgt/tgt.c, line 303, function main, PID 123025.Panic Expression rc== 65 PANIC_ID_tgt_1511773103687. /opt/emc/scaleio/sds/bin/sds-3.5.1100.107(mosDbg_PanicPrepare+0x13a) [0x93b62a] /opt/emc/scaleio/sds/bin/sds-3.5.1100.107(main+0x2ce) [0x4cd18e] /lib64/libc.so.6(__libc_start_main+0xf5) [0x7f72ec9c5555]
在客戶網站上單次遇到此問題時,由於記錄輪替,沒有 SDS 追蹤。
影響
系統將在單一故障點執行,萬一有其他元件故障,客戶將會遇到 DU 的情況。
Cause
未知 - 可疑的根本原因是已實作的特殊 SELinux 規則,但是這並不確定,並且僅因為這是客戶系統上唯一不尋常的因素,所以才被確定為可能的根本原因。
SDBG 伺服器啟動問題也可能是由於元件的 SDBG 偵聽埠正由系統上的另一個進程使用、資源不足以及其他作業系統相關問題引起的。
Resolution
因應措施
將 SDS 主機重新開機 - 主機重新開機可讓 SDS 正常啟動。
受影響的版本
未知 - 此問題發生在版本 3.5.1.1 上,但不清楚哪些版本受到影響。
已修正問題的版本
此問題未修復。
Affected Products
PowerFlex Software, VxFlex Product Family, VxFlex Ready Node, ScaleIO Ready Node-PowerEdge 13G, Ready Node SeriesArticle Properties
Article Number: 000203235
Article Type: Solution
Last Modified: 15 مايو 2026
Version: 5