VxRail: Event Code: VXR500TMP0203

Summary: This article gives details on the event code: VXR500TMP0203

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

VXR500TMP0203 

Message

CPU arg1 temperature is greater than the upper critical threshold.

Arguments

  • arg1 = CPU number

Cause

Some causes can be poor air flow, high inlet temperatures, fan obstruction, or sudden spikes in CPU utilization. 

Resolution

Environmental:

  1. Check system fans for obstructions.
  2. Check inlet thermal temperature.
  3. Verify that the ambient temperature is within thresholds.

Server:

To ensure the iDRAC is functioning correctly, power the drain node and monitor for reoccurrence. If physical access to the node is not available, perform a remote power drain VxRail: How to perform remote auxiliary power drain of a node through the iDRAC

System settings:

iDRAC9 may report CPU x temperature greater than the upper critical threshold events when the CPU workload spikes at or near CPU Power Max. When transient power bursts occur to meet additional CPU demand, the processor temperature may briefly exceed the upper critical threshold. For example, a server that is operating at 50-60% utilization and spikes to 100% utilization for 5-20 s may exceed the upper critical threshold for CPU temperature briefly. When this threshold is exceeded, events are recorded in the System event log and Lifecycle Log. When the peak transient spike is over and CPU temperature returns to normal, an event is recorded indicating CPU x temperature is within range. This is seen more often when c-states or on-demand Turbo Modes are active. iDRAC 4.22.00.00 and iDRAC9 4.40.00.00 contain improvements to thermal algorithms. 

Affected Products

VxRail Appliance Family, VxRail Appliance Series, VxRail G Series Nodes, VxRail D Series Nodes, VxRail D560, VxRail D560F, VxRail E Series Nodes, VxRail E560, VxRail E560F, VxRail E560N, VxRail E660, VxRail E660F, VxRail E660N, VxRail E665 , VxRail E665F, VxRail E665N, VxRail G560, VxRail G560F, VxRail P Series Nodes, VxRail P570, VxRail P570F, VxRail P580N, VxRail P670F, VxRail P670N, VxRail P675F, VxRail P675N, VxRail S Series Nodes, VxRail S570, VxRail S670, VxRail Software, VxRail V Series Nodes, VxRail V570, VxRail V570F, VXRAIL V670F, VxRail VD-4510C, VxRail VD-4520C, VxRail VD Series Nodes, VxRail VE-660, VxRail VE-6615, VxRail VE-670, VxRail VP-760, VxRail VP-7625, VxRail VP-770, VxRail VS-760 ...
Article Properties