SourceOne Console Error Occurs when Native Archive Folder Exceeds 2.1 Billion Items

Summary: SourceOne Console displays the error "An unexpected error has occurred" if a Native Archive folder has more than 2.1 billion items.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

The SourceOne Management Console displays the following error after clicking the Native Archive node: 

Description:
An unexpected error has occurred.
 
Additional Details:
Value was either too large or too small for an Int32.
 
Stack Trace:
   at System.Convert.ToInt32(Int64 value)
   at System.Int64.System.IConvertible.ToInt32(IFormatProvider provider)
   at System.Convert.ChangeType(Object value, Type conversionType, IFormatProvider provider)
   at System.Convert.ChangeType(Object value, Type conversionType)
   at Infragistics.Win.UltraWinDataSource.UltraDataColumn.ConvertToDataType(Object value, Type dataType)
   at Infragistics.Win.UltraWinDataSource.UltraDataColumn.ConvertToDataType(Object value)
   at Infragistics.Win.UltraWinDataSource.UltraDataRowsCollection.InternalInsert(Int32 index, Boolean raiseAddEvents, Object[] cellValues, Boolean bypassEditState)
   at Infragistics.Win.UltraWinDataSource.UltraDataRowsCollection.Insert(Int32 index, Boolean raiseAddEvents, Object[] cellValues, Boolean bypassEditState)
   at EMC.EX.MMCAdmin.PBAMMC.ExPBAArchiveFoldersViewCtrl.PopulateFoldersGrid()

Some archive folders may not be displayed after acknowledging the error. The folder which generated the error cannot be expanded. 

Cause

A software defect cited in SDR 60807 causes this error. Once the number of Volume Items in a single folder exceeds 2,152,631,789, the count can no longer be stored within a 32-bit integer variable.

Resolution

This issue is addressed in SourceOne Email Management versions 7.2 SP5 or later. SourceOne Patch and Service Packs are available for download on Dell Support Drivers & Downloads.

Affected Products

SourceOne Email Management