Connectrix B-Series: SNMP management tool cannot communicate with the Brocade switch

Summary: Connectrix B-Series: SNMP management tool cannot communicate with the Brocade switch.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

In this particular issue, SNMP was changed from SNMPv1 to SNMPv3.

 

Cause

On looking at the SNMPv3, config INFORMS were set to ON.

--SNMPv3 Entries-------------------------------

SNMP Informs = 1 (ON)

Informs are like an acknowledgment that a trap has been received. The trap recipient sends an 'inform' or 'ack' to acknowledge that the trap has been received and so the trap originator knows that it has been received and is not often used.

 

Resolution

Turn INFORMS off and check if that resolves your issue.

Switch:root> snmpconfig --set snmpv3

SNMP Informs Enabled (true, t, false, f): [false] false

 