Cisco: MDS 9700 with Supervisor 4 module resets

Summary: MDS 9700 switches with a supervisor 4 module (DS-X97-SF4-K9) may reboot, causing a switchover.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Issue only applies to MDS 9700 series switches using Supervisor 4 modules (DS-X97-SF4-K9).

A Supervisor 4 randomly resets. The show system reset-reason for the affected supervisor shows the reset reason as:

Reason: Kernel Panic

The following syslog message about 'device sdb4' may be logged:

%KERN-2-SYSTEM_MSG: [1294828.221287] EXT3-fs error (device sdb4): ext3_get_group_desc: Group descriptor not loaded - block_group = 0, group_desc = 0, desc = 0 - kernel

Cause

Cisco bug CSCvt32044   - Kernel Panic on supervisor 4

Note:  This issue only applies to MDS 9700 Supervisor 4 module (DS-X97-SF4-K9).

 

 

Resolution

Fix:
None

Workaround:
Disabling NTP may prevent the issue occurring.

Note: This issue is rare, and after switchover the switch appears healthy.

 

Affected Products

Connectrix MDS-9706, Connectrix MDS-9706-V2, Connectrix MDS-9710, Connectrix MDS-9710-V2, Connectrix MDS-9718