NMC - problems with refreshing vCenter information in NW 9.1
Summary: NMC - problems with refreshing vCenter information in NW 9.1
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
Environment:
Reason:
Connection to vCenter is timing out.
Solution:
The following environment variables need to be added:
- NetWorker 9.1.0.2
- NMC server on Windows 2012 R2
- NW server on Linux
- vCenter 5.5U3
NMC can display vCenter information in NMC when first opned after gstd started. At the time of first refresh the following error is displayed:
Error fetching vCwnter information for <cVnter name>
Reason(s): Dispatcher: Request timed out
and the view goes blank.
- NMC server on Windows 2012 R2
- NW server on Linux
- vCenter 5.5U3
NMC can display vCenter information in NMC when first opned after gstd started. At the time of first refresh the following error is displayed:
Error fetching vCwnter information for <cVnter name>
Reason(s): Dispatcher: Request timed out
and the view goes blank.
Reason:
Connection to vCenter is timing out.
Solution:
The following environment variables need to be added:
- On the NetWorker server please ad the following lines to /nsr/nsrrc file:
NSR_VBA_CONNECT_TIMEOUT=1200
export NSR_VBA_CONNECT_TIMEOUT
NSR_VBA_REQUEST_TIMEOUT=3600
export NSR_VBA_REQUEST_TIMEOUT
NSR_VBA_CPTAG_REQUEST_TIMEOUT=3600
export NSR_VBA_CPTAG_REQUEST_TIMEOUT
NSR_HYPERVISOR_QUERY_REQUEST_TIMEOUT=3600
export NSR_HYPERVISOR_QUERY_REQUEST_TIMEOUT
export NSR_VBA_CONNECT_TIMEOUT
NSR_VBA_REQUEST_TIMEOUT=3600
export NSR_VBA_REQUEST_TIMEOUT
NSR_VBA_CPTAG_REQUEST_TIMEOUT=3600
export NSR_VBA_CPTAG_REQUEST_TIMEOUT
NSR_HYPERVISOR_QUERY_REQUEST_TIMEOUT=3600
export NSR_HYPERVISOR_QUERY_REQUEST_TIMEOUT
- On the NMC server please add the System environment variable:
GST_VBA_TIMEOUT=7200
- Restart NetWorker server processes and gstd process if NMC is installed on a separate host.
Affected Products
NetWorker Management ConsoleProducts
NetWorker, NetWorker Management Console, VMware vCenter ServerArticle Properties
Article Number: 000022706
Article Type: How To
Last Modified: 17 نيسان 2026
Version: 5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.