NSM backups may fail with Error relinking snapvx snapshot to target: Unable to perform action Link on SnapVX snapshot, error SYMAPI_C_ACCESS_DENIED
Summary: NetWorker Snapshot Management (NSM) backups may fail with Error relinking snapvx snapshot to target: Unable to perform action Link on SnapVX snapshot, error SYMAPI_C_ACCESS_DENIED.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
NetWorker Snapshot Manager (NSM) snapvx backups fail with the following error message:
Error relinking snapvx snapshot to target: Unable to perform action Link on SnapVX snapshot, error SYMAPI_C_ACCESS_DENIED
Cause
The VMAX administrator has applied security settings using symacl and symauth to the Storage groups in VMAX used by NSM Application and data mover. This is not supported by NSM.
Resolution
Remove the security settings applied to the VMAX storage groups used by NSM Application and DataMover hosts.
VMAX Security Configuration Guide
NOTE: If additional assistance is required, consult with VMAX Support.
Affected Products
Enterprise Storage, NetWorkerProducts