IDPA: RUCK Error: file system is read-only
Summary: Rapid Upgrade Checker (RUCK) error due to
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
When running the Rapid Upgrade Checker (RUCK), you get the following error:
+-----------+-------------+--------+-----------------------------------+-----------------------------------------------+
| Component | Check | Status | Message | Remedy |
+-----------+-------------+--------+-----------------------------------+-----------------------------------------------+
| DPC | filesys_dpc | FAILED | File system check failed for: DPC | DPC file system is read-only. Contact Support |
| | | | | for assistance. |
+-----------+-------------+--------+-----------------------------------+-----------------------------------------------+
Where Conmponent is one of the following:
Avamar
DPA Server
DPA DS
DPA Agent
DPC
Search
RUCK gives one or more of the following check codes:
filesys_avamar
filesys_dpc
filesys_dpa_server
filesys_dpa_ds
filesys_dpa_agent
filesys_search_(/tmp)
filesys_search_(/mnt/search)
filesys_search_(/mnt/es_data)Cause
RUCK attempts to write a file on the server and this write fails with an error that the file system is read-only.
Resolution
NOTE: A fix for this issue has been added to the goidpa tool, follow the below KB to install goidpa:
Then run the following command on the ACM:
./goidpa system filesys-check
Then select the server that shows the error.
NOTE: If the issue persists, contact Dell Support for further assistance.