PowerSwitch: OS10: How to Check Switch ONIE and BIOS Versions
Summary: The purpose of this article is to provide instructions on how to verify what BIOS and ONIE versions are installed in the switch before updating OS10.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
To check what BIOS version the switch is running, issue the OS10 command: show system
OS10# show system Node Id : 1 MAC : f0:d4:e2:36:9e:cb Number of MACs : 128 Up Time : 22:01:01 Voltage : 12 Volts Current : 4 Amps Power : 52 Watts -- Unit 1 -- Status : up System Identifier : 1 Down Reason : user-triggered Digital Optical Monitoring : disable System Location LED : off Required Type : S4112F Current Type : S4112F Hardware Revision : A04 Software Version : 10.5.2.0P1 Physical Ports : 12x10GbE, 3x100GbE BIOS : 3.33.0.1-7 System CPLD : 1.1 Master CPLD : 0.2
To verify if the switch is up to date on the BIOS and ONIE versions, check the Dell Support website, referencing the service tag or switch model.
Note: In current versions of OS10 the PCIe, BIOS, BMC, Firmware Updater, ONIE, and SSD versions are all present in the output of the "
show system" command. Example below:
OS10# show system Node Id : 1 MAC : c8:f7:50:f0:ae:41 Number of MACs : 256 Up Time : 5 days 05:30:03 DiagOS : 3.00.3.41-2 PCIe Version : 2.6 -- Unit 1 -- Status : up System Identifier : 1 Down Reason : unknown Digital Optical Monitoring : disable System Location LED : off Required Type : S5248F Current Type : S5248F Hardware Revision : A01 Software Version : 10.6.0.1 Physical Ports : 48x25GbE, 4x100GbE, 2x200GbE BIOS : 3.40.0.9-17 BMC : 1.08 Firmware Updater : 3.40.5.1-26 ONIE : 3.40.1.1-9 SSD : L20B12 OCORE-FPGA@pci_0000_04_00.0 : 3.4 System CPLD : 0.9 Secondary CPLD 1 : 1.0 Secondary CPLD 2 : 1.0 Secondary CPLD 3 : 0.0 Secondary CPLD 4 : 0.0 ...
On older versions of OS10, to check the ONIE version on the switch, issue the command: system "/mnt/onie-boot/onie/tools/bin/onie-version"
OS10# system "/mnt/onie-boot/onie/tools/bin/onie-version" ONIE version : 3.40.1.1-6 ONIE vendor_id : 674 ONIE build_machine : dellemc_s5200_c3538 ONIE machine_rev : 0 ONIE arch : x86_64 ONIE build_platform : x86_64-dellemc_s5200_c3538-r0 ONIE config_version : 1 ONIE build_date : 2018-11-13T23:24-08:00 ONIE partition_type : gpt ONIE kernel_version : 4.9.30 ONIE firmware : auto ONIE switch_asic : bcm ONIE skip_ethmgmt_macs: no ONIE grub_image_name: grubx64.efi ONIE uefi_boot_loader: grubx64.efi ONIE uefi_arch : x64
Affected Products
MX Series, E Series, SmartFabric OS10 SoftwareArticle Properties
Article Number: 000190639
Article Type: How To
Last Modified: 10 آب 2026
Version: 5