PowerEdge: 16G - VPD access failed in RHEL kernel log for 24x2.5 NVMe Gen5 switch backplane
Summary: Observed "VPD access failed" in Red Hat Enterprise Linux (RHEL) kernel log for (CPU Direct Attach) 24x2.5 NVMe Gen5 switch backplane.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
PowerEdge 16G platforms with 24x2.5 NVMe switch active backplane, the following error message is logged in the kernel log, as shown in Figure 1.
Figure 1: Kernel log with "VPD access failed."
Cause
This issue is not related to hardware or firmware and does not affect any functional behavior of the backplane.
Support of Vital Product Data (VPD) capability is optional, and the NVMe switch active backplane does not implement this feature.
Support of Vital Product Data (VPD) capability is optional, and the NVMe switch active backplane does not implement this feature.
Resolution
This is working as designed.
Affected Products
PowerEdge R760, PowerEdge R760XA, PowerEdge R760xd2, PowerEdge R760xs, PowerEdge R7625, Red Hat Enterprise Linux Version 9, Red Hat Enterprise Linux Version 8Article Properties