Mainframe Enablers TF Clone/Snap: VOLUME Operation Completes with an EQCA128E Message Although the Operation Completes Successfully
Summary: During SNAP VOLUME operations, an erroneous EQCA128E message appears even though all functions successfully ran.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Error message is issued for SNAP VOLUME operations:
EQCA128E UNABLE TO DETERMINE REMOTE DA FOR SYSCALL EXECUTION -00-00-00-
Cause
This issue was introduced with C2403 maintenance for Mainframe Enablers 10.0.0 and 10.1.0.
*** TIMEFINDER MF SNAP V10.1.0 (019) - SCF V10.01.00 (0009) *** *** TIMEFINDER MF SNAP V10.0.0 (045) - SCF V10.00.00 (0064) ***
Resolution
Permanent Fix:
- For Mainframe Enablers (MFE) 10.1.0, Program Temporary Fix (PTF) SNA1024 is available to address the issue. Download the PTF from Dell Support.
- For Mainframe Enablers (MFE) 10.0.0, Program Temporary Fix (PTF) SNA0048 is available to address the issue. Download the PTF from Dell Support.
Additional Information
PTF Cover Letters:
MFE 10.1 SNA1024:
++PTF(SNA1024) REWORK(2024124) .
++VER(Z038) FMID(SSNPA10)
PRE(
SNA1020
)
/*
*-------------------------------------------------------------
* PROBLEM DESCRIPTION(S):
* ------------------------------------------------------------
* PROBLEM FIXED: MFE-17116
* USERS AFFECTED: SnapVX and TF/Clone users
* PROBLEM DESCRIPTION: Error message EQCA128E is displayed
* when running SnapVX or TF/Clone
* commands using remote syntax.
* DESCRIPTION DETAIL:
*
* Error message 'EQCA128E UNABLE TO DETERMINE REMOTE DA FOR
* SYSCALL EXECUTION 00-00-00' is displayed when running
* SnapVX or TF/Clone commands using remote syntax. This
* message should not be printed for VMAX/PowerMax systems
* running microcode 5876 or higher.
*
* PROBLEM RESOLUTION:
*
* SnapVX and TF/Clone have been updated to avoid printing the
* EQCA128E message for VMAX/PowerMax systems running microcode
* 5876 and higher.
*
* MODULES: EMCQCAPL
*
* ------------------------------------------------------------
* SNA1024 3 May 2024 18:02:38
* ------------------------------------------------------------
* OPT Summary
* The following OPT was addressed by this PTF:
*
* MFE-17116
*
*-------------------------------------------------------------
*/ .
MFE 10.0 SNA0048:
++PTF(SNA0048) REWORK(2024109) .
++VER(Z038) FMID(SSNPA00)
PRE(
SNA0047
)
/*
*-------------------------------------------------------------
* PROBLEM DESCRIPTION(S):
* ------------------------------------------------------------
* PROBLEM FIXED: MFE-17117
* USERS AFFECTED: SnapVX and TF/Clone users
* PROBLEM DESCRIPTION: Error message EQCA128E is displayed
* when running SnapVX or TF/Clone
* commands using remote syntax.
* DESCRIPTION DETAIL:
*
* Error message 'EQCA128E UNABLE TO DETERMINE REMOTE DA FOR
* SYSCALL EXECUTION 00-00-00' is displayed when running
* SnapVX or TF/Clone commands using remote syntax. This
* message should not be printed for VMAX/PowerMax systems
* running microcode 5876 or higher.
*
* PROBLEM RESOLUTION:
*
* SnapVX and TF/Clone have been updated to avoid printing the
* EQCA128E message for VMAX/PowerMax systems running microcode
* 5876 and higher.
*
* MODULES: EMCQCAPL
*
* ------------------------------------------------------------
* SNA0048 18 Apr 2024 19:55:53
* ------------------------------------------------------------
* OPT Summary
* The following OPT was addressed by this PTF:
*
* MFE-17117
*
*-------------------------------------------------------------
*/ .
Affected Products
Mainframe EnablersArticle Properties
Article Number: 000223689
Article Type: Solution
Last Modified: 09 حزيران 2026
Version: 2