Avamar: ConnectEMC HTTPS transport failing with unable to set a private key file
Summary: ConnectEMC fails to set the key file during Hypertext Transfer Protocol Secure (HTTPS), log shows a Privacy Enhanced Mail (PEM) key load failure at opt ConnectEMC. This failure is due to incorrect certificate key configuration. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
ConnectEMC HTTPS transport is failing with "unable to set a private key file." /opt/connectemc/logs/ConnectEMC_HTTP.log shows the following:
[2017-10-23 12:58:56] https://<ESRS-GW-IP>:443/incoming/RSC_1367372766-001E6775BBE8_102317_125846000.cec
[2017-10-23 12:58:56] Starting the CURL transfer ...
[2017-10-23 12:58:56] CURL Transfer complete
[2017-10-23 12:58:56] http failed unable to set private key file: '/opt/connectemc/' type PEM, error:58, cmd:https://<ESRS-GW-IP>:443/incoming
About to connect() to <ESRS-GW-IP> port 443 (#0)
Trying <ESRS-GW-IP>... connected
Connected to <ESRS-GW-IP> (<ESRS-GW-IP>) port 443 (#0)
unable to set private key file: '/opt/connectemc/' type PEM
Closing connection #0
[2017-10-23 12:58:56] HTTPS Transfer ended. Cause
The certificate and key configuration for the HTTPS transport is incorrect.
Resolution
Reconfigure the ConnectEMC transport settings using the Avamar Administrator Console to
- Change to Email if HTTPS transport is not the prefer option.
- Fix the HTTPS transport configuration
- For HTTPS transport, if using the default certificates, set the HTTPS settings to the following:
- For HTTPS transport, if using the default certificates, set the HTTPS settings to the following:
NOTE: The certificate file and key referenced here are stored on the Avamar system in the
/opt/connectemc/certs/ directory. For correct operation, these files and key must move one level up to /opt/connectemc/. In this situation, the private‑key passphrase is 'Default'.
Additional Information
Dell Connectivity is the replacement of ConnectEMC, when upgrading to the Avamar 19.10. ConnectEMC is removed, and the existing connectivity disconnects. Dell Connectivity is also known as Embedded Service Enabler (ESE).