PowerFlex:DIMM 硬件问题导致 CPU 使用率高和 SDS 分离

Summary: 日志条目报告从双列直插式内存模块 (DIMM) 和 CMCI 风暴消息中纠正的错误,导致 CPU 使用率导致 SDS 停止,从而增加延迟并断开 SDS 分离。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

问题描述 

某些内存问题(即 DIMM 问题)可能会导致 CMCI 风暴,进而导致 SDS 分离。

情景

出现此特殊问题的原因是操作系统未正确响应例行可纠正内存通知。

当服务器上的 RAM DIMM 模块出现故障时,也可能会发生这种情况,但其他硬件问题可能会导致相同的情况。 

症状

可以在 iDrac 或操作系统日志中观察到故障 DIMM,例如:

 kernel: {1}[Hardware Error]: Hardware error from APEI Generic Hardware Error Source: 4
 kernel: {1}[Hardware Error]: It has been corrected by h/w and requires no further action
 kernel: {1}[Hardware Error]: event severity: corrected
 kernel: {1}[Hardware Error]:  Error 0, type: corrected
 kernel: {1}[Hardware Error]:  fru_text: A1
 kernel: {1}[Hardware Error]:   section_type: memory error
 kernel: {1}[Hardware Error]:   error_status: 0x0000000000000400
 kernel: {1}[Hardware Error]:   physical_address: 0x0000000ad6a38ac0
 kernel: {1}[Hardware Error]:   node: 0 card: 0 module: 0 rank: 0 bank: 1 device: 1 row: 58311 column: 712
 kernel: {1}[Hardware Error]:   error_type: 13, scrub corrected error
 kernel: {1}[Hardware Error]:   DIMM location: not present. DMI handle: 0x0000
 kernel: {2}[Hardware Error]: Hardware error from APEI Generic Hardware Error Source: 65534
 kernel: {2}[Hardware Error]: It has been corrected by h/w and requires no further action
 kernel: {2}[Hardware Error]: event severity: corrected
 kernel: {2}[Hardware Error]:  Error 0, type: corrected
 kernel: {2}[Hardware Error]:   section type: unknown, xxxxxxxx-xxxx-xxxx-xxxx-000xxxxxxx1b
 kernel: {2}[Hardware Error]:  Error 1, type: corrected
 kernel: {2}[Hardware Error]:   section type: unknown, xxxxxxxx-xxxx-xxxx-xxxx-000xxxxxxx1b
 kernel: EDAC skx MC0: HANDLING MCE MEMORY ERROR
 kernel: EDAC skx MC0: CPU 0: Machine Check Event: 0x0 Bank 1: 0x940000000000009f
 kernel: EDAC skx MC0: TSC 0xcdaff277a3653a
 kernel: EDAC skx MC0: ADDR 0xad6a38ac0
 kernel: EDAC skx MC0: MISC 0x0
 kernel: EDAC skx MC0: PROCESSOR 0:0x50654 TIME 1669993821 SOCKET 0 APIC 0x0
 kernel: EDAC MC0: 0 CE memory read error on CPU_SrcID#0_MC#0_Chan#0_DIMM#0 (channel:0 slot:0 page:0xad6a38 offset:0xac0 grain:32 syndrome:0x0 -  err_code:0x0000:0x009f socket:0 imc:0 rank:0 bg:1 ba:1 row:0xe3c7 col:0x2c8)
 kernel: mce: [Hardware Error]: Machine check events logged
 mcelog: Hardware event. This is not a software error.
 mcelog: MCE 0
 mcelog: CPU 0 BANK 1 TSC cdaff277a3653a
 mcelog: ADDR ad6a38ac0
 mcelog: TIME 1669993821 Fri Dec  2 15:10:21 2022
 mcelog: MCG status:
 mcelog: MCi status:
 mcelog: Corrected error
 mcelog: Error enabled
 mcelog: MCi_ADDR register valid
 

检测到硬件问题后不久,报告 CMCI 风暴:

Dec  8 08:28:51 node01 kernel: CMCI storm detected: switching to poll mode
Dec  8 08:33:50 node01 kernel: CMCI storm subsided: switching to interrupt mode
(...)                
Dec 10 03:19:03 node01 kernel: CMCI storm subsided: switching to interrupt mode
Dec 10 03:19:03 node01 kernel: CMCI storm detected: switching to poll mode


高 CPU 使用率可能会导致 SDS 进程停止 IO(这将影响总体 I/O 系统延迟),甚至将 SDS 与 MDM 分离。如果在持续重建期间或另一个 SDS 遇到类似问题时发生这种情况,则可能会导致 DU 情况。

Cause

在 DIMM 错误期间,英特尔 CPU 可能会受到“中断风暴”的影响。根据 Red Hat 知识库:

从CPUID将DisplayFamily_DisplayModel报告为06H_1AH的45 nm 英特尔 64处理器开始,处理器可以报告有关已纠正的机器检查错误的信息,并为软件提供可编程中断以响应MC错误,称为已纠正的机器检查错误中断(CMCI)。当错误级别超过可编程阈值时,英特尔的硬件可以提供中断。如果错误仍然存在,则 CPU 将以足够高的速率持续收到大量涌入或中断风暴,以至于影响 CPU 执行有用工作的能力。发生这种情况时,内核会禁用 CMCI 机制,并恢复为定期轮询机器检查错误的更经典方法。错误率降低后,内核会重新启用 CMCI。

有关更多信息,请访问:持续记录“内核:CMCI 风暴消退”错误(外部链接)
 

此问题可能会导致 CMCI 风暴,这也可能由操作系统功能和软件触发,这些功能和软件拦截可纠正错误,而不是允许由 Dell iDRAC 捕获和处理它们。当 EDAC 和 CMCI 都已启用时,通常会发生这种情况。

 

Resolution

将受影响的 SDS 置于维护模式和/或将其从群集中删除,以减轻对整个系统的影响。

联系硬件供应商以检查是否有任何潜在的硬件问题。如果未检测到硬件问题(特别是在出现可纠正错误的情况下),请联系操作系统供应商并请求帮助禁用 EDAC 和 CMCI。 

Additional Information

受影响的版本

不适用 — 不是 PowerFlex 问题

已修复问题的版本

不适用 — 硬件问题

Affected Products

PowerFlex rack, VxFlex Ready Nodes, ScaleIO