PowerStore: PUHC mislykkedes med "Systemet stødte på uventede backend-fejl. Kontakt support"
Summary: PUHC mislykkedes – Systemet stødte på uventede backend-fejl. Kontakt support. (0xE0101001000C)
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Under en PowerStoreOS-kodeopgradering mislykkedes tilstandskontrollen før opgraderingen.
Cause
Årsagen logges fra PowerStore-nodejournalloggen.
Sep 28 22:56:54.847708 ASSET-A control-path[124493]: 2021-09-28 22:56:54.847 [NDU] [INFO] [com.emc.cyclone.contexts.infrastructure.ndu.application.NDUCommonUtil.ApplianceUpgradeUtil|vert.x-eventloop-thread-0] [72fee6ed-bc69-47f6-a4e3-05d8ac9deb1d|9b3b14a3-e90d-4fee-914d-1ac253b28bb1|fetchApplianceSessionInfo] Platform request to fetch appliance session id completed successfully1 Sep 28 22:56:54.847772 ASSET-A control-path[124493]: 2021-09-28 22:56:54.847 [NDU] [INFO] [com.emc.cyclone.contexts.infrastructure.ndu.application.NDUCommonUtil.ApplianceUpgradeUtil|vert.x-eventloop-thread-0] [72fee6ed-bc69-47f6-a4e3-05d8ac9deb1d|9b3b14a3-e90d-4fee-914d-1ac253b28bb1|fetchApplianceSessionInfo] Is rollback failed state on the appliance upgrade session is null Sep 28 22:56:54.954970 ASSET-A control-path[124493]: 2021-09-28 22:56:54.954 [NDU] [INFO] [com.emc.cyclone.contexts.infrastructure.ndu.application.NDUCommonUtil.AwaitResponsesFromPlatformUtil|vert.x-eventloop-thread-0] [72fee6ed-bc69-47f6-a4e3-05d8ac9deb1d|9b3b14a3-e90d-4fee-914d-1ac253b28bb1|prestageHandleResponse] Platform request completed successfully Sep 28 22:57:24.996368 ASSET-A control-path[124493]: 2021-09-28 22:57:24.996 [NDU] [ERROR] [com.emc.cyclone.contexts.infrastructure.services.platform.gateway.application.upgrade.service.cycloneCommandService.PrestageUpgradePackageAS|vert.x-eventloop-thread-0] [72fee6ed-bc69-47f6-a4e3-05d8ac9deb1d] Prestage failed: (with error 'java.lang.Exception: ERROR: 15G free space is required. Clean up the space under /cyc_cfs and try again.
Forklaring
Det cyc_fs filsystem bruges til at gemme supportmateriale, diagnostiske filer, og den plads, der forbruges af disse, administreres normalt automatisk. I nogle få sjældne tilfælde blev for mange støttematerialer bevaret, hvilket forårsagede, at ledig plads i cyc_fs var lav.
Resolution
Brug brugergrænsefladen i PowerStore Manager eller Service Shell-scriptet svc_dc til at fjerne ældre dataindsamlinger for at frigøre plads i cyc_fs.
Affected Products
PowerStore 1000TProducts
PowerStore, PowerStore 3000T, PowerStore 5000T, PowerStore 9000TArticle Properties
Article Number: 000192404