PowerScale: Proces isi_quota_notify_d se nezdařil.

Summary: V clusteru se zaprotokolují události oznamující, že proces isi_quota_notify_d selhal.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Události ukazují, že isi_quota_notify_d proces has failed je zaznamenán do clusteru. 


Event:  (Process isi_quota_notify_d failed)
 

AMST11-CL02-1# isi event events view 3347

          ID: 3347
     Started: 09/06 17:20
Causes Long: Process isi_quota_notify_d failed
         Lnn: 15
       Devid: 15
  Last Event: 2017-09-06T17:20:14
      Ignore: No
Ignore Time: Never
    Resolved: No
Resolve Time: Never
       Ended: --
      Events: 1
    Severity: warning




Zprávy protokolu:

2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Daemon initialized. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: 
   Daemon obtained master lock 2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: flxapi initialized. 2017-09-06T17:58:43+02:00 <3.3> AMSTxx-CL02-2 
   isi_quota_notify_d[30374]: Node is not having external IP. Releasing master lock. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Exiting.

Cause

Uzel, na kterém běží isi_quota_notify_d služba nemá externí IP adresu.

Resolution

Chcete-li zachovat isi_quota_notify_d musí mít každý uzel v řešení Isilon externí IP adresu.

Affected Products

Isilon NL410

Products

Isilon NL410
Article Properties
Article Number: 000164453
Article Type: Solution
Last Modified: 11 ديسمبر 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.