PowerScale: Processen isi_quota_notify_d mislykkedes
Summary: Hændelser viser, at isi_quota_notify_d processen mislykkedes, logges på klyngen.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Begivenhederne viser, at isi_quota_notify_d Processen mislykkedes, logges på klyngen. Event: (Process isi_quota_notify_d failed)
AMST11-CL02-1# isi event events view 3347 ID: 3347 Started: 09/06 17:20 Causes Long: Process isi_quota_notify_d failed Lnn: 15 Devid: 15 Last Event: 2017-09-06T17:20:14 Ignore: No Ignore Time: Never Resolved: No Resolve Time: Never Ended: -- Events: 1 Severity: warning
Logbeskeder:
2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Daemon initialized. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Daemon obtained master lock 2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: flxapi initialized. 2017-09-06T17:58:43+02:00 <3.3> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Node is not having external IP. Releasing master lock. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Exiting.
Cause
Den node, der kører isi_quota_notify_d tjenesten har ikke en ekstern IP-adresse.
Resolution
For at bevare isi_quota_notify_d service fra at mislykkes, skal hver node i Isilon have en ekstern IP-adresse.