PowerScale: Processen isi_quota_notify_d mislykkedes

Summary: Hændelser viser, at isi_quota_notify_d processen mislykkedes, logges på klyngen.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Begivenhederne viser, at isi_quota_notify_d Processen mislykkedes, logges på klyngen. 


Event:  (Process isi_quota_notify_d failed)
 

AMST11-CL02-1# isi event events view 3347

          ID: 3347
     Started: 09/06 17:20
Causes Long: Process isi_quota_notify_d failed
         Lnn: 15
       Devid: 15
  Last Event: 2017-09-06T17:20:14
      Ignore: No
Ignore Time: Never
    Resolved: No
Resolve Time: Never
       Ended: --
      Events: 1
    Severity: warning




Logbeskeder:

2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Daemon initialized. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: 
   Daemon obtained master lock 2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: flxapi initialized. 2017-09-06T17:58:43+02:00 <3.3> AMSTxx-CL02-2 
   isi_quota_notify_d[30374]: Node is not having external IP. Releasing master lock. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Exiting.

Cause

Den node, der kører isi_quota_notify_d tjenesten har ikke en ekstern IP-adresse.

Resolution

For at bevare isi_quota_notify_d service fra at mislykkes, skal hver node i Isilon have en ekstern IP-adresse.