Hendelser viser at isi_quota_notify_d Prosessen mislyktes logges på klyngen. Event: (Process isi_quota_notify_d failed)
AMST11-CL02-1# isi event events view 3347 ID: 3347 Started: 09/06 17:20 Causes Long: Process isi_quota_notify_d failed Lnn: 15 Devid: 15 Last Event: 2017-09-06T17:20:14 Ignore: No Ignore Time: Never Resolved: No Resolve Time: Never Ended: -- Events: 1 Severity: warning
Loggmeldinger:
2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Daemon initialized. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Daemon obtained master lock 2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: flxapi initialized. 2017-09-06T17:58:43+02:00 <3.3> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Node is not having external IP. Releasing master lock. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Exiting.
Cause
Noden som kjører isi_quota_notify_d tjenesten har ikke en ekstern IP-adresse.
Resolution
Hvis du vil beholde isi_quota_notify_d Hvis tjenesten mislykkes, må hver node i Isilon ha en ekstern IP-adresse.