VxRail: Event Code: VXR508SSD0001
Summary: The "Write" Endurance of solid state drive (SSD) arg1 is less than the threshold value of Remaining Write Rated Endurance.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
iDRAC event SSD0001 occurs and YELLOW alarm 'VXR508SSD0001' present in the vCenter portal.
Cause
The "Write" Endurance of solid state drive identified in the message is less than the threshold value of Remaining Write Rated Endurance.
Resolution
To confirm if this test is a false positive or not:
- Collect a support assist log, also called TSR, for the node, see: PowerEdge: Export a SupportAssist Collection Using iDRAC UI or racadm cmd
- Clear system event log, see: PowerEdge: How to View or Clear the System event log
- Reset the iDRAC, see: PowerEdge: How to Reset the Integrated Dell Remote Access Controller (iDRAC)
Performing an iDRAC reset forces the iDRAC to re-inventory the controller and disk health status. Wait 5-10 minutes after the reset and check the remaining disk endurance from the physical disk page. If the error persists, contact support and provide the TSR collected in step 1: Contact Technical Support | Dell US
Note: If the event code “VXR508SSD0001: Write Endurance of SSD is below the threshold value” is observed, it may be identified as a false positive alert and can be safely ignored.
Affected Products
VxRail, VxRail D560F, VxRail E560F, VxRail E660F, VxRail E665F, VxRail G560F, VxRail P570F, VxRail P670F, VxRail P675F, VxRail V570F, VXRAIL V670FArticle Properties