SRM, SRA: Fejlen TestFailover mislykkes: Kunne ikke oprette snapshot af replika Test_CG

Summary: TestFailover på Storage Resource Manager (SRM) mislykkes. SRA-kommandoen (Storage Replication Adapter) 'testFailoverStart' mislykkedes for konsistensgruppen med fejlen – "Kunne ikke oprette snapshot af replikakonsistensgruppe Test_CG. SRA-kommandoen 'testFailoverStart' mislykkedes for konsistensgruppen 'Test_CG' Ugyldig konfiguration fundet i indstillingsfilen Se EmcSrdfSra-logfiler for at få flere oplysninger om fejlen." ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Fejl i EmcSrdfSra.log:
SraDevicePairings::GetCopyInfo ] [WARNING]: A valid CopyInfo block could not be found in the options file that has Symm [0002975xxxxx]
TestFailoverStopCommand::AutoTargetDeviceProvisioning] AutoTargetDevice feature is Disabled
TestFailoverStopCommand::RunOnGroup] [ERROR]: Invalid CopyInfo type specified in TestFailoverConfig file. Exiting with failure

[20230602132024    18   304 FileExists@Utilities.cpp        ] [WARNING]: Filename:/srm/sra/conf/EmcSrdfSraTestFailoverConfig.xml
[20230602132024    18   112 main@EmcSrdfSra.cpp             ] [WARNING]: Cannot find Sra Test Failover Device Pairings configuration file. 

 

Cause

For at udføre TestFailover er det vigtigt at have en kilde- og målenhed. Kildeenheden er R2-enheden på genoprettelseswebstedet. Target er snapshot-destinationsenheden. 
Her blev hverken EmcSrdfSraGlobalOptions.xml eller EmcSrdfSraTestFailoverConfig.xml opdateret.

Resolution

Trin til opdatering EmcSrdfSraGlobalOptions.xml:
Rediger nedenstående parametre-
AutoTargetDevice = Yes
AutoTargetDeviceReuse = No
TerminateCopySession = Yes 
BEMÆRK: Værdien af indstillingen Automatisk genbrug af målenhed skal være modsat af TerminateCopySessions som bedste praksis. 

ELLER

Opdater EmcSrdfSraTestFailoverConfig.xml. 
Eksempel på, hvordan du opdaterer EmcSrdfSraTestFailoverConfig.xml:
<CopyInfo>
<ArrayId>000190300186</ArrayId>
<CopyType>SNAPVX</CopyType>
<CopyMode>NOCOPY</CopyMode>
<SavePoolName></SavePoolName>
<DeviceList>
<DevicePair>
<Source>4D8</Source>
<Target>4DE</Target>
</DevicePair>
<DevicePair>
<Source>4D9</Source>
<Target>4DF</Target>
</DevicePair>
</DeviceList>
</CopyInfo>

Additional Information

Dell EMC SRDF-adapter indeholder følgende indstillingsfiler under mappen ProgramData\EMC\EmcSrdfSra\Config:
  • EmcSrdfSraGlobalOptions.xml
  • EmcSrdfSraTestFailoverConfig.xml
  • EmcSrdfSraProtectionSiteGoldCopyConfig.xml
  • EmcSrdfSraRecoverySiteGoldCopyConfig.xml
  • EmcSrdfSraDeviceMaskingControl.xml

I den seneste version kan den indsamles ved at starte SRM Appliance Management ved hjælp af <SRM_Appliance_FQDN>:5480 > Download konfigurationsarkiv -
  1. Log på VMware SRM Appliance Management Interface.
  2. Gå til Storagereplikeringsadaptere>Dell EMC SRDF-adapter.
  3. Vælg Menu (tre prikker) >Download konfigurationsarkiv.

Download konfigurationsarkiv

4) Den downloadede fil har filnavnet <buildname>_<buildTAG>.tar.gz.

Trin, der skal følges for at redigere konfigurationsarkivet i Windows:
  1. Højreklik på det downloadede <buildname>_<buildTAG>.tar.gz. Åbn filen ved hjælp af 7zip. 
  2. Vælg den fil, der skal ændres, og højreklik for at redigere
Rediger den nødvendige fil EmcSrdfSraGlobalOptions.xml
     3. Foretag ændringerne i filen, og gem den. 
     4. Klik på Ja på nedenstående prompter-5
Vælg Ja for at opdatere den relevante xml-fil
. Derefter skal den sradocker.tar fil gemmes.

Klik på Ja for at opdatere sradocker.tar

       5. Upload konfigurationsarkiv-
Upload konfigurationsarkiv
6. Genindlæs-
Indstillingen Genindlæsning af Dell EMC SRDF-adapter i rullemenuen
 
 
 

Affected Products

Storage Replication Adapter (SRA), Solutions Enabler
Article Properties
Article Number: 000228483
Article Type: Solution
Last Modified: 20 يناير 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.