ECS:呼叫总部 - Ref_ID:BtreeDiskLevelGC - 症状代码:1325
Summary:
这是 ECS 3.3 中引入的呼叫总部功能,用于检测 警报。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
ECS 系统已呼叫总部并显示以下警报。
<?xml version="1.0" encoding="UTF-8"?>
<ConnectHome SchemaVersion="1.0.8"
xsi:schemaLocation="/opt/connectemc/schema/ema_ConnectHome108.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<TransType>10</TransType>
<TransTypeDesc>EventXML</TransTypeDesc>
<TransID>0</TransID>
<Node Status="Unknown" State="Unknown" ID="psnt1">
<Identifier>
<DeviceState>1</DeviceState>
<DeviceStatus>1</DeviceStatus>
<ClarifyID>psnt1</ClarifyID>
<SiteName>UNKNOWN</SiteName>
<Vendor>EMC</Vendor>
<DeviceType>ElasticCloudStorageApp</DeviceType>
<Model>ElasticCloudStorage</Model>
<SerialNumber>psnt1</SerialNumber>
<WWN>ECSQE00077</WWN>
<Platform>platform</Platform>
<OS>SLES</OS>
<OS_VER>12.3</OS_VER>
<UcodeVer>3.3.0.0-4352.834410f</UcodeVer>
<EmbedLevel>2</EmbedLevel>
<InternalMaxSize>512800</InternalMaxSize>
<Comment>Object Alert</Comment>
</Identifier>
<Connection>
<ConnectType>ESRS</ConnectType>
<IPName>sandy-maize.ecs.lab.emc.com</IPName>
<ConnectNum>169.254.197.2</ConnectNum>
<Port>22</Port>
</Connection>
<HeartBeat>
<HBStatus></HBStatus>
<HBState></HBState>
</HeartBeat>
<InternalData>
<FileList/>
<EventList>
<Event>
<SymptomCode>1325</SymptomCode>
<Category>Configuration</Category>
<Severity>Warning</Severity>
<Status>Unknown</Status>
<Component>Object</Component>
<ComponentID></ComponentID>
<SubComponent>BTREE Disk GC</SubComponent>
<SubComponentID></SubComponentID>
<CallHome>true</CallHome>
<FirstTime>2019-01-29T20:05:09.755Z</FirstTime>
<LastTime>2019-01-29T20:05:09.755Z</LastTime>
<Count>0</Count>
<EventData><![CDATA[]]></EventData>
<Description><![CDATA[Capacity free-up throughput is too slow to catch up with system metadata garbage collection. Please involve ECS engineering. [Ref_ID : BtreeDiskLevelGC]]]></Description>
</Event>
</EventList>
</InternalData>
<ExternalFiles/>
</Node>
</ConnectHome>
Cause
Btree GC 在磁盘容量可用阶段运行缓慢。如果等待删除的垃圾超过 1 TB,并且垃圾区块回收率与垃圾容量回收率之间的差异大于 100 GB,则会生成此警报。当系统处于此状态 7 天后,将发送警报。
Resolution
- 通过 putty 会话连接到群集中的一个节点。
- 验证当前传感器状态。
命令:
svc_rest_cmd /vdc/sensor/status/BtreeDiskLevelGC
# svc_rest_cmd /vdc/sensor/status/BtreeDiskLevelGC
svc_rest_cmd 1.0.10
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<SensorStatusList>
<SensorId>BtreeDiskLevelGCC</SensorId>
<ListSensorStatus>
<SensorStatusRestRep>
<ContextId>BtreeDiskLevelGC</ContextId>
<CurrentState>OK</CurrentState>
<NodeId>47b32995-35fc-4593-8f3c-39c878fb10ad</NodeId>
<PreviousState>OK</PreviousState>
<Time>1551104230509</Time>
</SensorStatusRestRep>
</ListSensorStatus>
- <查找 CurrentState>,如果设置为 OK,则错误处于非活动状态,这可能是误报。请忽略该警报,但如果在下周内再次触发,则向技术支持部门提出服务请求