AppSync: Applikasjonstilordning mislyktes under søk etter virtuelle VPLEX-volumer

Summary: AppSync isunable get the virtual volumes information with wwn: fra VPLEX på grunn av problemer med VPLEX-administrasjonskonsollen.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

AppSync kan ikke hente informasjon om virtuelt volum med wwn:<wwn_id> fra VPLEX-klynge på grunn av problemer med VPLEX-administrasjonskonsollen.
AppSync-kommandoen mislyktes:https://xxx.xx.xxx.xxx:443/vplex/export+storage-view+find HTTP/1.1
 
Den primære feilen som ble funnet i serverloggen, er:
 

Failure attempting to update properties 'storage-views' on\n Export.\ncause:        Infinite eller NaN\n"
 

Du finner detaljer rundt denne feilen i serverloggen som vist her: 
 

<date>  10:07:20.697 INFO [Thread-404] [com.emc.archway.restclient.RESTClient] [xxxx] [] executeRequest: executing POST: POST https://xxx.xx.xxx.xxx:443/vplex/export+storage-view+find HTTP/1.1
<date>  10:07:20.822 INFO [Thread-404] [com.emc.archway.restclient.RESTClient] [xxxx] [] executeRequest: Response Status Line: HTTP/1.1 541
<date>  10:07:20.822 ERROR [Thread-404] [com.emc.archway.restclient.RESTClientRequest] [xxxx] [] Response is
<date>  10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXClient] [xxxx] [] Exception Occurred: RESTClientUnexpectedResponseCodeException, Message: {    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXClient] [xxxx] [] +++The following stack trace is abbreviated.+++
<date>  10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] Exception Occurred: VPLEXRequestFailedException, Message: {    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXClient.sendSingleVplexRequest(VPLEXClient.java:206) [top 3 frames]
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.executeCLICommand(VPLEXServiceBean.java:1161) [top 3 frames]
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.getStorageViewsInfosContainingWwn(VPLEXServiceBean.java:1418) [top 3 frames]
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.getVirtualVolumeIdFromWwn(VPLEXServiceBean.java:914)
<date>  10:07:21.088 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] VPLEXRequestFailedException while finding virtual volume with wwn:<wwn_id>  in cluster:cluster-1 error:{    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:21.635 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] VPLEXRequestFailedException while finding virtual volume with wwn:<wwn_id>  in cluster:cluster-1 error:{    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:21.807 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [VNX_000072]: 172.xx.xx.xx\E:\ were mapped to array CKM00xxxx. If the array is a VNX, XtremIO, VPLEX Cluster, VNXe or Unity array, register CKM00xxxxxx. If the array is a VMAX array, register EMC SMI-S Provider managing the VMAX Array.(METADATA: TYPE-INFO, TIME-2017-06-13 10:07:21.807+0100NATIVETIME-2017-06-13 10:07:21.807+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
<date>  10:07:21.872 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [GENL_000044]: The following application items could not be mapped to any configured storage system: xxxx-SQL-01:ReportServerTempDB.Register the required storage system in AppSync.(METADATA: TYPE-WARNING, TIME-2017-06-13 10:07:21.872+0100NATIVETIME-2017-06-13 10:07:21.872+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
<date>  10:07:21.888 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [SPP_000037]: Cannot determine the storage type where application xxxx-SQL-01:ReportServerTempDB resides. Verify if the application is located on a supported EMC storage that has been added to AppSync.(METADATA: TYPE-ERROR, TIME-2017-06-13 10:07:21.872+0100NATIVETIME-2017-06-13 10:07:21.872+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)



Cause

Dette problemet er relatert til VPLEX-administrasjonskonsollen som avviser gyldige kommandoer som sendes fra AppSync via REST API. Dette er et kjent problem i VPLEX.

Årsaken til NaN-problemet antas for tiden å være CST JNI-innfødt kode som ikke er trådsikker og ødelegger FPU-registrene og forstyrrer andre java-tråder som trenger å bruke FPU (for eksempel for doble tall).

Resolution

Permanent løsning:
Dette problemet er løst i VPLEX GeoSynchrony-kode versjon 6.0 Service Pack 1 Patch 4 og nyere.

Løsningen:

  1. Start VPLEX-administrasjonskonsollen på nytt.
  2. Kjør Serviceplanen for AppSync på nytt.

Hvis du vil ha mer informasjon om hvordan du starter tjenesten VPLEX Management Console på nytt, kan du se KB-artikkelen 000167777: ViPR-kontroller: Oppretting av en VPLEX-distribuert LUN mislykkes med status 524: Infinite eller NaN 


Additional Information


 
 

Affected Products

AppSync

Products

AppSync, VPLEX Series
Article Properties
Article Number: 000057099
Article Type: Solution
Last Modified: 17 أبريل 2026
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.