AppSync:应用程序映射在查找 VPLEX 虚拟卷时失败

Summary: AppSync 无法使用 WWN 获取虚拟卷信息: 由于 VPLEX 管理控制台问题而导致的 VPLEX。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

由于 VPLEX 管理控制台问题,AppSync 无法从 VPLEX 群集获取具有 wwn:<wwn_id> 的虚拟卷信息。
AppSync 命令失败:https://xxx.xx.xxx.xxx:443/vplex/export+storage-view+find HTTP/1.1
 
服务器日志中发现的主要错误是:
 

尝试在\n 导出时刷新属性“storage-views”失败。\n原因:        Infinite 或 NaN\n”
 

有关此错误的详细信息可在服务器日志中找到,如下所示: 
 

<date>  10:07:20.697 INFO [Thread-404] [com.emc.archway.restclient.RESTClient] [xxxx] [] executeRequest: executing POST: POST https://xxx.xx.xxx.xxx:443/vplex/export+storage-view+find HTTP/1.1
<date>  10:07:20.822 INFO [Thread-404] [com.emc.archway.restclient.RESTClient] [xxxx] [] executeRequest: Response Status Line: HTTP/1.1 541
<date>  10:07:20.822 ERROR [Thread-404] [com.emc.archway.restclient.RESTClientRequest] [xxxx] [] Response is
<date>  10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXClient] [xxxx] [] Exception Occurred: RESTClientUnexpectedResponseCodeException, Message: {    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXClient] [xxxx] [] +++The following stack trace is abbreviated.+++
<date>  10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] Exception Occurred: VPLEXRequestFailedException, Message: {    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXClient.sendSingleVplexRequest(VPLEXClient.java:206) [top 3 frames]
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.executeCLICommand(VPLEXServiceBean.java:1161) [top 3 frames]
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.getStorageViewsInfosContainingWwn(VPLEXServiceBean.java:1418) [top 3 frames]
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.getVirtualVolumeIdFromWwn(VPLEXServiceBean.java:914)
<date>  10:07:21.088 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] VPLEXRequestFailedException while finding virtual volume with wwn:<wwn_id>  in cluster:cluster-1 error:{    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:21.635 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] VPLEXRequestFailedException while finding virtual volume with wwn:<wwn_id>  in cluster:cluster-1 error:{    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:21.807 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [VNX_000072]: 172.xx.xx.xx\E:\ were mapped to array CKM00xxxx. If the array is a VNX, XtremIO, VPLEX Cluster, VNXe or Unity array, register CKM00xxxxxx. If the array is a VMAX array, register EMC SMI-S Provider managing the VMAX Array.(METADATA: TYPE-INFO, TIME-2017-06-13 10:07:21.807+0100NATIVETIME-2017-06-13 10:07:21.807+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
<date>  10:07:21.872 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [GENL_000044]: The following application items could not be mapped to any configured storage system: xxxx-SQL-01:ReportServerTempDB.Register the required storage system in AppSync.(METADATA: TYPE-WARNING, TIME-2017-06-13 10:07:21.872+0100NATIVETIME-2017-06-13 10:07:21.872+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
<date>  10:07:21.888 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [SPP_000037]: Cannot determine the storage type where application xxxx-SQL-01:ReportServerTempDB resides. Verify if the application is located on a supported EMC storage that has been added to AppSync.(METADATA: TYPE-ERROR, TIME-2017-06-13 10:07:21.872+0100NATIVETIME-2017-06-13 10:07:21.872+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)



Cause

此问题与 VPLEX 管理控制台相关,该控制台拒绝通过 REST API 从 AppSync 传递的有效命令。这是 VPLEX 中的已知问题。

目前认为 NaN 问题的原因在于 CST JNI 本机代码不是线程安全的,损坏了 FPU 寄存器,并干扰了需要使用 FPU 的其他 Java 线程(例如双精度数字)。

Resolution

永久解决方案:
此问题已在 VPLEX GeoSynchrony 代码版本 6.0 Service Pack 1 Patch 4 及更高版本中得到修复。

解决 方案:

  1. 重新启动 VPLEX 管理控制台。
  2. 重新运行 AppSync 服务计划。

有关如何重新启动 VPLEX 管理控制台服务的更多详细信息,请参阅知识库文章 000167777:ViPR Controller :VPLEX 分布式 LUN 的创建失败,状态为 524:Infinite 或 NaN 


Additional Information


 
 

Affected Products

AppSync

Products

AppSync, VPLEX Series
Article Properties
Article Number: 000057099
Article Type: Solution
Last Modified: 17 أبريل 2026
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.