PowerEdge: Systemet henger under POST med UEFI0136 Kan ikke kjøre CSIOR

Summary: Løsning for serverhenging under POST med feil UEFI136 på grunn av utilgjengelig Lifecycle Controller-fastvare under CSIOR-kjøring

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Følgende feil kan oppstå under POST:
 

UEFI0136: Unable to execute CSIOR (Collect System Inventory on Restart) because the Lifecycle Controller (LC) firmware was not accessible.
Do one of the following: 1) Restart the system and retry the operation. 2) Update the iDRAC firmware. If the issue persists, contact your service provider

 

SLN305470_en_US__1CSIOR_Error
 

Cause

Lifecycle Controller er ikke tilgjengelig med CSIOR-feilmelding.

Resolution

  1. Kontroller at LifeCycle Controller (LCC)-kontrolleren er aktivert i iDRAC-innstillingene i systemoppsett F2.
  2. Sjekk eventuelle USB-enheter (det vil si tastatur, mus, USB-harddisker) som er direkte koblet til serveren. Fjern disse enhetene og test resultatene.
  3. Hvis problemet fremdeles ikke er løst, må du kontrollere om en KVM-svitsj er koblet til serveren. For feilsøkingsformål må du fjerne KVM fra serveren for å bekrefte om problemet vedvarer
  4. Kontroller at all maskinvare er oppdatert, inkludert BIOS, LCC og IDRAC.


Serveren kan startes uten CSIOR-operasjonen, trykk F1 for å fortsette oppstarten. Det anbefales å planlegge et vedlikeholdsvindu for å undersøke og løse problemet.

Affected Products

C Series, HS Series, Modular Infrastructure, Rack Servers, Tower Servers, XE Servers, iDRAC8, iDRAC9, Lifecycle Controllers, OEM Server Solutions

Products

XR Servers
Article Properties
Article Number: 000143332
Article Type: Solution
Last Modified: 05 مايو 2026
Version:  6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.