DELL Unity: Refreshing replication remote connection between Unity 5.1.2 and VNXe2 will fail (User Correctable)
Summary: Refreshing replication remote connection between Unity 5.1.2 and VNXe2 will fail during the "Refresh remote system connections on local system" step.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Error Code;0x6500128
Error Code: 0x100a - "Refresh remote system connections on local system (failed)"
Log errors showing:
This is happening right before it tries refreshing the replication interconnects.
Error Code: 0x100a - "Refresh remote system connections on local system (failed)"
Log errors showing:
"[
{"en-US":"The expression str is not supported. (Error Code:0x7d1312a)"}
]"
This is happening right before it tries refreshing the replication interconnects.
\spx\EMC\CEM\log\cemtracer_dataprotection.log
03 Mar 2022 19:50:27 - [RESTClient] ERROR - {0:1881678:506552869}[30175|1511|d83ffb40][handleError @ /c4_working/Unity_PullRequest_Build_Driver_Sles15_RTM_1.1/infrastructureproviders/components/RESTClient/src/RESTSession.cpp:1187] request https://10.8.1.137/api/types/replicationInterface/instances?fields=instanceId%2Cid%2CnasServer%2CipPort%2Chealth%2CinterfaceIpAddress%3A%3A%40str%28ipAddress%29%2CipProtocolVersion%2Cname failed: 131150122 {"error":{"errorCode":131150122,"httpStatusCode":422,"messages":[{"en-US":"The expression str is not supported. (Error Code:0x7d1312a)"}],"created":"2022-03-03T19:50:27.112Z"}} 03 Mar 2022 19:50:27 - [RESTClient] ERROR - {0:1881678:506690709}[30175|1511|d83ffb40][getInstances @ /c4_working/Unity_PullRequest_Build_Driver_Sles15_RTM_1.1/infrastructureproviders/components/RESTClient/src/RESTSession.cpp:797] Caught exception: /c4_working/Unity_PullRequest_Build_Driver_Sles15_RTM_1.1/infrastructureproviders/components/RESTClient/src/RESTSession.cpp:1213 code: 131150122, message: REST request failed: {"error":{"errorCode":131150122,"httpStatusCode":422,"messages":[{"en-US":"The expression str is not supported. (Error Code:0x7d1312a)"}],"created":"2022-03-03T19:50:27.112Z"}}Cause
This is due to a code fix for another issue that was introduced in Unity OE 5.1. It adds the STR Function into a REST query. The VNXe2 does not support the STR Function.
Resolution
Fixed in Unity OE 5.2.0.0.5.173 and newer.