Symptoms

可以在以下位置观察到以下错误消息:  /var/log/microservice_log/dayone.log
 

'vsphere_cluster_finalization.vsphere_cluster_finalization.cluster_system_vm_storage_policy_apply.default.cluster_system_vm_storage_policy_apply', 'state': 'STARTED', 'progress': 77, 'status': {'id': 'cluster_system_vm_storage_policy_apply', 'internal_id': 'vsphere_cluster_finalization.vsphere_cluster_finalization.cluster_system_vm_storage_policy_apply.default.cluster_system_vm_storage_policy_apply_False____cxxxxxxxxxxxxxxxxxxx', 'internal_family': 'vsphere_cluster_finalization.vsphere_cluster_finalization.cluster_system_vm_storage_policy_apply.default.cluster_system_vm_storage_policy_apply', 'status': 'STARTED', 'startTime': 1659622536686, 'stage': 'default', 'params': {'vc_conn_info': {'host': 'hostname.xxxxxx', 'username': 'administrator@xxxx.xxxx', '****** 'port': xxx}, 'datacenter_name': 'xxxxx', 'cluster_name': 'cxxxx'}, 'error': {'result': {'error': {'code': 'E3100_Cluster_19', 'params': ['VxRail Manager'], 'message': 'Failed to apply vm VxRail Manager storage policy'}}}}}"

Cause

结果发现,管理网络上启用了 vSAN 见证流量,并使用管理 IP (vmk0) 而不是 vSAN IP 更新了单播代理程序列表。

显示 vmk0 已启用 vSAN 流量的错误屏幕截图 

Resolution

 使用 CLI 命令禁用了 vmk0(管理 IP)上的 vSAN 见证流量:

esxcli vsan network ip remove -I vmk0 -T witness


vmk0 上的 VMkernel 适配器使用管理流量进行了更新,VxRail 节点上的单播代理程序列表使用 vSAN IP (vmk1) 详细信息进行了更新。请参阅下面的屏幕截图:

显示正确流量的屏幕截图 


 

Affected Products

VxRail, VxRail Appliance Series, VxRail Software
Article Properties
Article Number: 000202375
Article Type: Solution
Last Modified: 15 مايو 2026
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.