VMAX AFA and PowerMax: VDM Cannot Load After DM Panic Due to Blocked Threads When Running Embedded NAS 8.1.15.401 and NFSv4
Summary: The VDM cannot load after a DataMover (DM) panic due to blocked threads. This issue occurs when Embedded NAS (eNAS) is running version 8.1.15.401 with NFSv4.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
The VDM cannot load after a DataMover (DM) panic due to blocked threads. This issue occurs when eNAS is running version 8.1.15.401 with NFSv4.
The following entries are from the Logs:
Aug 8 07:59:57 2022:DART:KERNEL:ERROR:3:Slot 2:::1659959974:ThreadsServicesSupervisor: Service:NFSD Pool:NFSD_v4Daemons BLOCKED for 422 seconds: Server operations may be impacted . Aug 8 07:59:57 2022:DART:KERNEL:ERROR:3:Slot 2:::1659959974:ThreadsServicesSupervisor: Service:NFSD Pool:NFSD_Exec BLOCKED for 400 seconds: Server operations may be impacted .
Cause
- There is a defect in the NFSv4_ClientList::Clean() code.
- Upgrading to Cumulative E-Pack 5978.711.711_9699 or 9734 upgrade the eNAS version to 8.1.15.401. This upgrade introduces exposure if a file system is mounted with NFSv4.
Resolution
- For customers running eNAS version 8.1.15.401 (released in Cumulative E-Packs 5978.711.711_9699 and 9734) with NFSv4-mounted file systems, the recommendation is to remount the file system with NFSv3.
- For customers running eNAS version 8.1.15.401, submit an E-Pack request for eNAS version 8.1.15.402.
Affected Products
PowerMax, Symmetrix, VMAXArticle Properties
Article Number: 000202531