Data Domain: NVRAM-fejl registreret | Fejl eller defekt tilstand
Summary: NVRAM og dens BBU (Battery Backup Unit) er kritiske komponenter i Data Domain Data Invulnerability Architecture. Data Domain Operating System (DDOS) overvåger disse komponenter. Hvis der opstår en hardwarefejl, genererer DDOS en advarsel, der skal adresseres øjeblikkeligt for at bevare systemets integritet. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
⚠️ Vigtigt! Udskift ikke et NVRAM-kort eller en BBU, medmindre DDOS har udsendt en advarsel, der indikerer fejl. Proaktiv udskiftning anbefales ikke.
Gælder for:
- Alle Data Domain-systemer
- Alle DDOS-softwareversioner
Mulige advarsler:
NVRAM-00001: File system is disabled due to a problem with the NVRAM subsystemNVRAM-00002: Battery at low charge and not chargingNVRAM-00003: Excessive PCI or memory errorsNVRAM-00201: Hardware fault detected with NVRAM cardNVRAM-00202: Hardware fault detected with NVRAM remote batteryNVRAM-00204: Invalid condition detected with NVRAM battery
Cause
DDOS overvåger kontinuerligt NVRAM-delsystemet. Når den registrerer en fejl i NVRAM-kortet eller BBU'en, sender den en advarsel.
Advarslen indeholder typisk diagnostiske oplysninger, men det kan være nødvendigt med yderligere undersøgelser, hvis udskiftning af komponenten ikke løser problemet.
Resolution
Løsning af advarslen indebærer generelt udskiftning af NVRAM-kortet eller BBU (hvis det ikke er integreret). Følg disse trin:
- Opret en supportpakke
- Opret en serviceanmodning hos din supportudbyder.
Nyttige CLI-kommandoer:
-
# alerts show current # Check for active NVRAM or battery alerts # system show nvram # Review card errors and battery status # system show hardware # Confirm NVRAM card presence
⚠️Bemærk: En batteriopladning under 100 % er normalt. DDOS styrer batteriets tilstand ved jævnligt at aflade og genoplade det.
Additional Information
Eksempel:
- Her ser vi en god NVRAM - Nul 'Fejl' & alle batteristatusser er 'OK' (selvom opladningen er på ~ 96%)
sysadmin@itsaDD# system show nvram
NVRAM Cards:
Card Component Value
---- ------------------- -----------------------------------------------
1 Slot 10
Firmware version 2.0.4
Memory size 3.93 GiB
Errors 0 memory (0 uncorrectable), 0 PCI, 0 controller
Board temperature 35 C
CPU temperature 41 C
Number of batteries 4
Card model no 313-163-100A-02
Card serial no FLA011301nnnnn
Battery model no 313-164-100A-01
Battery serial no FLA021242nnnnn
---- ------------------- -----------------------------------------------
NVRAM Batteries:
Card Battery Status Charge Charging Time To Temperature Voltage
Status Full Charge
---- ------- ------ ------ -------- ----------- ----------- -------
1 1 ok 96 % enabled 0 mins 26 C 8.088 V
2 ok 95 % enabled 0 mins 27 C 8.082 V
3 ok 97 % enabled 0 mins 25 C 8.084 V
4 ok 95 % enabled 0 mins 26 C 8.072 V
---- ------- ------ ------ -------- ----------- ----------- -------
Affected Products
Data Domain, PowerProtect Data Protection Appliance, Data Domain Deduplication Storage Systems, Integrated Data Protection Appliance Family, PowerProtect Data Protection HardwareArticle Properties
Article Number: 000204334
Article Type: Solution
Last Modified: 31 أكتوبر 2025