PowerFlex 3.X:网关 UI 404 错误
Summary: 在 RCM 升级期间,登录到 PowerFlex GatewayUI 显示 404 错误。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
- 网关已使用 RCM 3.6.5 进行升级
- 登录 PowerFlex Gateway UI,可以看到以下内容:

- 网关scaleio.log显示以下输出:
2024-02-08 09:13:09,094 [localhost-startStop-1] ERROR c.e.s.s.services.RequestMapUtils - vasa.provider.monitor.interval.seconds (60,60) must be a number between -2147 483648, 2147483647.
影响
在网关可用之前,升级无法继续。
Cause
“/opt/emc/scaleio/gateway/webapps/ROOT/WEB-INF/classes/gatewayUser.properties“文件中有许多参数不正确地附加了逗号,并且该值已在行中。
示例:
vasa.provider.ips=, vasa.provider.monitor.port=, vasa.provider.monitor.interval.seconds=60,60 #vasa.provider.replica.set.name=vasa-rs .. lia.ldap.commands.batch.size=256,256 upload.commands.batch.size=16,16 lia.upload.commands.batch.size=256,256 validate.node.commands.batch.size=256,256 cloudiq.enabled=true,true
Resolution
可以通过设置”/opt/emc/scaleio/gateway/webapps/ROOT/WEB-INF/classes/gatewayUser.properties“参数添加到它们应该是什么。如果不确定,请使用另一个网关进行比较。该示例并非详尽无遗。附加了错误参数的更多行。
在上面的示例中,各行应如下所示:
vasa.provider.ips= vasa.provider.monitor.port= vasa.provider.monitor.interval.seconds=60 #vasa.provider.replica.set.name=vasa-rs .. lia.ldap.commands.batch.size=256 upload.commands.batch.size=16 lia.upload.commands.batch.size=256 validate.node.commands.batch.size=256 cloudiq.enabled=true
空行删除了逗号,删除了包含实际值的行的逗号和额外值。
完成此作后,重新启动网关服务:
# systemctl restart scaleio-gateway
受影响的版本
PowerFlex RCM 3.6.5
已修复问题的版本
PowerFlex RCM 3.8.8