Data Domain: Troubleshooting Network Interface Errors and Transmit Queue Timeouts

Summary: This article describes how to identify and resolve network‑card-related errors reported in kern.info, bios.log, and system logs on Data Domain systems. These errors commonly involve transmit queue timeouts, unsupported modules, hardware faults, and firmware-related issues across Broadcom, QLogic, and Intel NICs. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

Scenario #1: Broadcom tg3 - Transmit Queue Timeout

Symptom:
This issue is seen with Broadcom cards.
ethMa may lose network connection due to tg3 firmware issue.
NETDEV WATCHDOG: <interface> (<driver>): transmit queue <#> timed out
ethMa (tg3): transmit queue 0 timed out
Example:
May 14 19:52:52 datadomain kernel: [8823179.817976] (E4)NETDEV WATCHDOG: ethMa (tg3): transmit queue 0 timed out
Resolution: 
 

Scenario #2: Broadcom bnx2x - Transmit Queue Timeout

Symptoms: 
Transmit queue timeout, issue seen with Broadcom cards
eth1a (bnx2x): transmit queue 7 timed out
Example:
May  1 01:12:12 datadomain kernel: [9207895.910222][   C61] (E4)NETDEV WATCHDOG: eth1a (bnx2x): transmit queue 7 timed out
Resolution:
Upgrade DDOS version to DDOS 8.2 or higher release.
 

Scenario #3: QLogic qede - Tx Timeouts

Symptom:
This issue is seen with QLogic cards,
Network I/O operations fail with Tx timeouts in the DDOS logs.
ethMc (qede): transmit queue 2 timed out
Example:
Nov 28 04:37:16 datadomain kernel: [ 6654.391364][ C0] (E4)NETDEV WATCHDOG: ethMc (qede): transmit queue 2 timed out
 
Resolution:
Upgrade DDOS version to DDOS 8.1 or higher. Also run below command to set the transmit timeout to 60.
# net option set ql_tx_timeout 60
 

Scenario #4: Intel ice - Transmit Queue Timeout

Symptom:
Transmit queue timeout
ethMc (ice): transmit queue 2 timed out
This issue is seen with Intel 25 Gbps /100 Gbps Nic cards.
Resolution:
Upgrade DDOS version to DDOS 8.3 or higher.
 

Scenario #5: Unsupported SFP+ Module

Symptom:
An unsupported SFP+ module type was detected.
Example:
May 12 04:58:45 datadomain kernel: [92453.417985] (E4)i40e 0000:19:00.0: Rx/Tx is disabled on this device because an unsupported SFP+ module type was detected. 
Resolution:
Based on the DDR model, order the SFP from the Dell Data domain support site.
 

Scenario #6: Intel ixgbe - Tx Unit Hang

Symptom:
ethMa: Detected Tx Unit Hang
Example:
Oct 21 21:21:58 datadomain kernel: [4011120.505166] (E4)ixgbe 0000:19:00.0 ethMa: Detected Tx Unit Hang
Resolution:
Replace the PCI Riser Card.
Sometimes, the NIC card may also need replacement.
 

Scenario #7: QLogic - MFW Not Responsive

Symptom:
The MFW is not responsive.
Example:
May 10 06:58:07 datadomain kernel: [1610244.578575] (E4)[qed_mcp_cmd_and_union:666(eth10c-0)]The MFW is not responsive. Avoid sending mailbox command 0x001a0000 [param 0x00000001].
Resolution:
Upgrade DDOS to 7.9 or higher releases.
 

Scenario #8: QLogic Hardware Error (DMAE Failure)

Symptom:
HW error occurred
Example:
May 10 06:58:07 datadomain kernel: [1610244.601613] (E4)[qed_hw_error_occurred:2414(eth10c-0)]HW error occurred [DMAE Failure]
Resolution:
Upgrade the DDOS to 7.9 or higher releases.
 

Scenario #9: QLogic - qede_tx_timeout

Symptom:
qede_tx_timeout
Example:
Jun 6 11:29:05 datadomain kernel: [3959072.479810] (E4)[qede_tx_timeout:923(eth10a)]Tx timeout!
Resolution:
Upgrade the DDOS to 8.1 or higher and configure the CLI command to set timeout "net option set ql_tx_timeout 60."
 
Also refer to the following knowledge articles:

Scenario #10: Device Not Detected

Symptom:
Device not detected
Example:
Device not detected: QLogic 4x10GE QL41164HFCU CNA - 34:80:0D:CC:6A:C8(NIC in Slot 8 Port 1 Partition 1)
Resolution:
Reseat the NIC; if reseating did not help, then replace the NIC.
 

Scenario #11: HWC8607 - Lost Communication with NIC.

Symptom:
HWC8607 | The data communication with the device NIC is lost.
Example:
29388 | HWC8607 | 2021-04-26 05:07:58 | The data communication with the device NIC in Slot 4 running on the port 1 is lost.

29404 | HWC8607 | 2021-04-26 05:10:55 | The data communication with the device NIC in Slot 4 running on the port 2 is lost.
Resolution:
Upgrade the DDOS to 7.9 or higher releases.
Also refer to the following knowledge articles:

Affected Products

Data Domain
Article Properties