PowerFlex 4.x Opgradering af Dell PowerSwitch-switche

Summary: Dette afsnit omhandler procedurerne til opgradering af Dell PowerSwitch- og Cisco Nexus-switche. Procedurerne for opgradering af Cisco Nexus-switche kan variere afhængigt af den NX-OS-version, der kører på Cisco Nexus-switchene. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

Opgradering af Dell PowerSwitch-switche

PowerFlex Manager understøtter flere Dell PowerSwitch-modeller med specifikke firmware- og softwarekomponenter.

Du skal opgradere switchene i følgende rækkefølge:

  • Administrationsswitche
  • Adgangsafbrydere
  • Sammenlægningsswitche
Følgende arbejdsgang er relevant under opgradering af Dell PowerSwitch-switchene i en ny PowerFlex Manager:
  1. Opgrader Dell PowerSwitch-switchene
  2. Opgrader OS-softwareversionen
  3. Opgrader BIOS-versionen
  4. Opgrader BMC-versionen
  5. Opgrader FPGA-versionen
  6. Opgrader ONIE-versionen

 

Opgrader Dell PowerSwitch-switche ved hjælp af PowerFlex Manager

Brug denne procedure til at opgradere Dell PowerSwitch-switchene i PowerFlex Manager.

Om denne opgave

IC til standardoverholdelse bruges altid til delte ressourcer, f.eks. switche.
SEDDEL:Hvis der anvendes delvis netværksautomatisering, skal du se Dell PowerFlex-enhed med PowerFlex 4.x-administrationsvejledning for at få oplysninger om manuelle switchopgraderinger.
SEDDEL:For PowerFlex-versioner før 4.5 skal firmwarekomponenterne opdateres manuelt for alle andre Dell-switche end softwarekomponenterne.

Forudsætninger

Sørg for, at du har taget en sikkerhedskopi af switchkonfigurationerne. Se Sikkerhedskopiering af miljøet for at få flere oplysninger.

Trin

  1. Log på PowerFlex Manager.
  2. Opdater switchene én ad gangen. Gå til siden Ressourcer, vælg en switch, i højre side skal du klikke på Ikke-kompatibel med standardkatalog.
  3. Klik på Opdater ressourcer.
  4. Klik på Anvend opdateringer > Ja.
    SEDDEL:Sørg for at opdatere switchene én ad gangen. Vælg ikke flere switche, og opdater dem alle samtidigt. Den mindst krævede version af Open Network Install Environment (ONIE) er 3.40.1.1-6. Før du bruger ONIE-firmwareopdateringsprogrammet, skal du først opgradere switchen til dette minimumskrav, hvis din switch har en ONIE-version, der er lavere end 3.40.1.1-6.
    SEDDEL:VRF (virtuel routing og videresendelse) understøttes kun, når den har et netværk, der dirigeres til PowerFlex Manager-grænsefladen. De fleste kundeudrulninger ved hjælp af lag-2 kan ikke bruge VRF-standardgrænsefladen.

Opgrader Dells operativsystem og firmware manuelt

Dell OS- og firmwareopgraderinger udføres af PowerFlex Manager. Den manuelle procedure er kun til reference. Du kan finde flere oplysninger i: Installations-, opgraderings- og nedgraderingsvejledning til Dell SmartFabric OS10PowerFlex Manager understøtter ikke PCIe-firmwareopgradering på Dell PowerSwitch-switche. Denne opgradering udføres manuelt.

 

Opgrader PCIe-firmwaren på switche i Dell PowerSwitch S5200-serien

Brug denne procedure til at opgradere PCIe-firmwaren på switche i Dell PowerSwitch S5200-serien.

Om denne opgave

SEDDEL:Filnavnet og versionerne i denne procedure er angivet som et eksempel. De angivne trin er kun til reference.

Forudsætninger

Sørg for, at du har adgang til følgende:
  • OS10-versionen er 10.5.x.x. Hvis ikke, skal du følge IC en for at opgradere til OS10 10.5.x.x.
    • Sørg for, at firmwarekomponenterne svarer til IC'en.
  • Den nyeste PCIe-firmwareversion. Download den nyeste PCIe-firmwareversion x.x fra Dell Technologies-supportwebstedet (f.eks.: onie-update-full-x86_64-dellemc_s5200_c3538-r0.3.40.5.1-24.zip).
  • En seriel konsol til at få adgang til switchen.
  • IP-adresse eller USB-forbindelse fra switch for at få adgang til PCIe-firmwarefilen.

Trin

  1. SSH til switchens administrations-IP-adresse og -type: Vis system.
    Eksempel på output:
    s5200-switch# show system
    Node Id : 1
    MAC : 3c:2c:30:7d:74:80
    Number of MACs : 384
    Up Time : 14 weeks 09:32:24
    DiagOS : 3.00.3.41-3
    PCIe Version : 2.1
    
    -- Unit 1 --
    Status : up
    System Identifier : 1
    Down Reason : unknown
    Digital Optical Monitoring : disable
    System Location LED : off
    Required Type : S5232F
    Current Type : S5232F
    Hardware Revision : A00
    Software Version : 10.5.4.5
    Physical Ports : 32x100G, 2x10GbE
    ONIE : 3.40.1.1-9
    BMC : 1.07
    BIOS : 3.40.0.9-15
    OCORE-FPGA@pci_0000_04_00.0 : 3.4
    Firmware Updater : 3.40.5.1-24
    SSD : L20B12
    System CPLD : 0.8
    Secondary CPLD 1 : 1.0
    Secondary CPLD 2 : 1.0
    Secondary CPLD 3 : 0.0
    Secondary CPLD 4 : 0.0
    Download PDF-filen fra Dell Networking Firmware Updater v3.40.5.1-26 til S5248F-ON-switch, og sammenlign systemet med minimumssystemkravene.
  2. Godkend ONIE-versionen, skriv: sudo / mnt / onie-boot / onie / tools / bin / onie-version.
    Eksempel på output:
    ONIE version : 3.40.1.1-9
    ONIE vendor_id : 674
    ONIE build_machine : dellemc_s5200_c3538
    ONIE machine_rev : 0
    ONIE arch : x86_64
    ONIE
    Validate PCIE Firmware Version build_platform : x86_64-dellemc_s5200_c3538-r0
    ONIE config_version : 1
    ONIE build_date : 2022-05-02T16:29-07:00
    ONIE partition_type : gpt
    ONIE kernel_version : 4.9.30
    ONIE firmware : auto
    ONIE switch_asic : bcm
    ONIE skip_ethmgmt_macs: no
    ONIE grub_image_name: grubx64.efi
    ONIE uefi_boot_loader: grubx64.efi
    ONIE uefi_arch : x64
  3. Godkend PCIe-firmwareversionen, skriv: sudo hshell -c 'pciephy fw version'.
    Eksempel på output:
    s5200-switch# system "sudo hshell -c 'pciephy fw version'"
    0:soc_flash_init: Flash supported ID = 0x20
    PCIe FW loader version: 2.1
    PCIe FW version: D102_04
  4. Kopier den nye PCIe-firmwarefil til switchen.
    SEDDEL:PCIe-firmwarefilen er et bundt i firmware-ZIP-filen.
    1. Pak onie-update-full-x86_64-dellemc_s5200_c3538-r0.3.40.5.1-24.zip ud.
    2. Brug den udpakkede fil fra trin a til at pakke XGS_PCIe_gen3_Firmware_02_06_TH3_TD3.zip ud.
    3. Kopier den pcieg3fw.bin fil fra XGS_PCIe_gen3_Firmware_02_06_TH3_TD3.zip til FTP-serveren i stien: /pub/dell/S5200/PCI/fw2.6
    Eksempel på output:
    S5200-switch# Kopiér ftp://anonymous@10.10.185.188/pub/dell/S5200/PCI/fw2.6/pcieg3fw.binhome://pcieg3fw.bin
    kodeord:
    Kopieringen lykkedes
    SEDDEL:Andre OS10-understøttede metoder såsom SCP og USB kan også bruges, men er ikke dokumenteret her.
  5. Kontroller, at den nye PCIe-firmwarefil er tilgængelig, skriv: dir home.
    Eksempel på output:
    s5200-switch# dir home
    
    Directory contents for folder: home
    Date (modified) Size (bytes) Name
    --------------------- ------------ ------------------------------------------
    2023-05-02T06:13:18Z 30720 pcieg3fw.bin
    s5200-switch# system "sudo -i"
    root@s5200-switch:~# cd /home/admin
    root@s5200-switch:/home/admin# ls
    pcieg3fw.bin
    root@s5200-switch:/home/admin#
  6. Opret forbindelse til switchens serielle konsol, skriv: s5200-switch-console#.
  7. Luk alle Ethernet-grænseflader på switchen, skriv:
    S5200-switch-console# Konfigurer terminal
    S5200-switch-console(config)# Grænsefladeområde E1/1/1-1/1/34
    S5200-switch-console(conf-range-eth1/1/1-1/1/34)# nedlukning
    Eksempel på output:
    <165>1 2023-05-02T06:27:05.376621+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/1
    <165>1 2023-05-02T06:27:05.377845+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_OSTATE_DN: Interface operational state is down :ethernet1/1/1
    <165>1 2023-05-02T06:27:05.383505+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %OSPFV2_ADJ_CHANGE: OSPF Process VRF default 7, Nbr 10.234.83.25 on ethernet1/1/1 state changed to DOWN
    <165>1 2023-05-02T06:27:05.402105+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/2
    <165>1 2023-05-02T06:27:05.402174+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_OSTATE_DN: Interface operational state is down :ethernet1/1/2
    <165>1 2023-05-02T06:27:05.404604+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %OSPFV2_ADJ_CHANGE: OSPF Process VRF default 7, Nbr 10.234.83.33 on ethernet1/1/2 state changed to DOWN
    <165>1 2023-05-02T06:27:05.415249+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/5
    <165>1 2023-05-02T06:27:05.426259+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/6
    <165>1 2023-05-02T06:27:05.432995+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/7
    <165>1 2023-05-02T06:27:05.438967+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/8
    <165>1 2023-05-02T06:27:05.446299+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/9
    <165>1 2023-05-02T06:27:05.454274+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/10
    <165>1 2023-05-02T06:27:05.464857+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/11
    <165>1 2023-05-02T06:27:05.479749+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/12
    s5200-switch-console(conf-range-eth1/1/1-1/1/34)# <165>1 2023-05-02T06:27:05.479835+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_OSTATE_DN: Interface operational state is down :ethernet1/1/11
    <165>1 2023-05-02T06:27:05.492594+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/13
    <165>1 2023-05-02T06:27:05.492760+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_OSTATE_DN: Interface operational state is down :ethernet1/1/12
    <165>1 2023-05-02T06:27:05.492911+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %STP_ROOT_CHANGE: STP:Root Brg Chg RPVST root changed for vlan 1.
    <165>1 2023-05-02T06:27:05.493250+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %STP_ROOT_CHANGE: STP:Root Brg Chg My ID:3c2c.307d.7480 OldRt:1:3c2c.307d.6a00 NewRt:4097:3c2c.307d.7480
    <165>1 2023-05-02T06:27:05.503099+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/14
    <165>1 2023-05-02T06:27:05.513631+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/15
    <165>1 2023-05-02T06:27:05.522458+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/16
    <165>1 2023-05-02T06:27:05.530299+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/17
    <165>1 2023-05-02T06:27:05.539176+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/18
    <165>1 2023-05-02T06:27:05.546300+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/19
    <165>1 2023-05-02T06:27:05.553108+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/20
    <165>1 2023-05-02T06:27:05.559141+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/21
    <165>1 2023-05-02T06:27:05.565057+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/22
    <165>1 2023-05-02T06:27:05.571422+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/23
    <165>1 2023-05-02T06:27:05.578553+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/24
    <165>1 2023-05-02T06:27:05.584956+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/25
    <165>1 2023-05-02T06:27:05.591664+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/26
    <165>1 2023-05-02T06:27:05.598589+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/27
    <165>1 2023-05-02T06:27:05.608060+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/28
    <165>1 2023-05-02T06:27:05.618760+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/29
    <165>1 2023-05-02T06:27:05.627611+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/30
    <165>1 2023-05-02T06:27:05.646174+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/31
    <165>1 2023-05-02T06:27:05.646960+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_OSTATE_DN: Interface operational state is down :ethernet1/1/31
    <165>1 2023-05-02T06:27:05.788040+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/32
    <165>1 2023-05-02T06:27:05.921872+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_OSTATE_DN: Interface operational state is down :ethernet1/1/32
    <165>1 2023-05-02T06:27:05.922760+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_OSTATE_DN: Interface operational state is down :port-channel10
    <165>1 2023-05-02T06:27:05.922944+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_OSTATE_DN: Interface operational state is down :vlan10
    <165>1 2023-05-02T06:27:05.923008+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %LACP_PORT_UNGROUPED: Interface exited port-channel port-channel10 : ethernet1/1/31
    <165>1 2023-05-02T06:27:05.923079+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %OSPFV2_ADJ_CHANGE: OSPF Process VRF default 7, Nbr 10.234.83.37 on vlan10 state changed to DOWN
    <165>1 2023-05-02T06:27:05.929663+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %STP_ROOT_CHANGE: STP:Root Brg Chg RPVST root changed for vlan 10.
    <165>1 2023-05-02T06:27:05.929961+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %STP_ROOT_CHANGE: STP:Root Brg Chg My ID:3c2c.307d.7480 OldRt:10:3c2c.307d.6a00 NewRt:4106:3c2c.307d.7480
    <165>1 2023-05-02T06:27:05.930335+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %STP_ROOT_CHANGE: STP:Root Brg Chg RPVST root changed for vlan 67.
    <165>1 2023-05-02T06:27:05.930458+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %STP_ROOT_CHANGE: STP:Root Brg Chg My ID:3c2c.307d.7480 OldRt:67:3c2c.307d.6a00 NewRt:4163:3c2c.307d.7480
    <165>1 2023-05-02T06:27:05.934420+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %STP_ROOT_CHANGE: STP:Root Brg Chg RPVST root changed for vlan 68.
    <165>1 2023-05-02T06:27:05.935704+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %STP_ROOT_CHANGE: STP:Root Brg Chg My ID:3c2c.307d.7480 OldRt:68:3c2c.307d.6a00 NewRt:4164:3c2c.307d.7480
    <165>1 2023-05-02T06:27:05.935812+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %LACP_PORT_UNGROUPED: Interface exited port-channel port-channel10 : ethernet1/1/32
    <165>1 2023-05-02T06:27:05.935896+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/33
    <165>1 2023-05-02T06:27:05.938199+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/34
    <165>1 2023-05-02T06:27:05.946947+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/3:1
    <165>1 2023-05-02T06:27:05.954930+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :ethernet1/1/4:1
    s5200-switch-console(conf-range-eth1/1/1-1/1/34)# exit
    
        
  8. Grænseflade til nedlukningsstyring på switchen, skriv:
    S5200-switch-console(config)# interface mgmt 1/1/1
    S5200-switch-console(conf-if-ma-1/1/1)# nedlukning
    Eksempel på output:
    s5200-switch-console(conf-if-ma-1/1/1)# <165>1 2023-05-02T06:28:01.217946+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_ASTATE_DN: Interface admin state down :mgmt1/1/1
    <165>1 2023-05-02T06:28:01.224865+00:00 s5200-switch-console dn_alm 728 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IFM_OSTATE_DN: Interface operational state is down :mgmt1/1/1
    s5200-switch-console(conf-if-ma-1/1/1)# end
    
        
  9. Kontroller, at alle Ethernet- og administrationsgrænseflader er slukket ned, skriv: s5200-switch-console# vis interfacestatus.
    Eksempel på output:
    --------------------------------------------------------------------------------------------------
    Port Description Status Speed Duplex Mode Vlan Tagged-Vlans
    --------------------------------------------------------------------------------------------------
    Eth 1/1/1 lab1-gw1 down 0 full -
    Eth 1/1/2 lab1-gw2 down 0 full -
    Eth 1/1/3:1 lab1-mgmt down 0 full T 10 -
    Eth 1/1/4:1 down 0 full A 10 -
    Eth 1/1/5 down 0 full A 1 -
    Eth 1/1/6 down 0 full A 1 -
    Eth 1/1/7 down 0 full A 1 -
    Eth 1/1/8 down 0 full A 1 -
    Eth 1/1/9 down 0 full A 1 -
    Eth 1/1/10 down 0 full A 1 -
    Eth 1/1/11 down 0 full A 1 -
    Eth 1/1/12 down 0 full A 1 -
    Eth 1/1/13 down 0 full A 1 -
    Eth 1/1/14 down 0 full A 1 -
    Eth 1/1/15 down 0 full A 1 -
    Eth 1/1/16 down 0 full A 1 -
    Eth 1/1/17 down 0 full A 1 -
    Eth 1/1/18 down 0 full A 1 -
    Eth 1/1/19 down 0 full A 1 -
    Eth 1/1/20 down 0 full A 1 -
    Eth 1/1/21 down 0 full A 1 -
    Eth 1/1/22 : down 0 full A 1 -
    Eth 1/1/23 down 0 full A 1 -
    Eth 1/1/24 down 0 full A 1 -
    Eth 1/1/25 down 0 full A 1 -
    Eth 1/1/26 down 0 full A 1 -
    Eth 1/1/27 down 0 full A 1 -
    Eth 1/1/28 down 0 full A 1 -
    Eth 1/1/29 down 0 full A 1 -
    Eth 1/1/30 down 0 full A 1 -
    Eth 1/1/31 down 0 full -
    Eth 1/1/32 down 0 full -
    Eth 1/1/33 down 0 full A 1 -
    Eth 1/1/34 down 0 full A 1 -
    --------------------------------------------------------------------------------------------------
    
    s5200-switch-console#
  10. Opdater PCIe-firmwareversionen, skriv: sudo -i
    Eksempel på output:
    s5200-switch-console# system "sudo -i"
    [sudo] password for admin:
    root@s5200-switch-console:~# cd /home/admin
    root@s5200-switch-console:/home/admin# ls
    pcieg3fw.bin
    root@s5200-switch-console:/home/admin# hshell
    Welcome to the NPU Shell
    type ::exit to exit the shell and ::[npu] to change the default npu
    ** Idle timeout 300 secs **
    
    SAI.0> pwd
    Working Directory: /
    SAI.0> cd /home/admin
    SAI.0> pwd
    Working Directory: /home/admin/
    SAI.0> ls
    pcieg3fw.bin
    SAI.0> pciephy fw load pcieg3fw.bin
    0:soc_flash_init: Flash supported ID = 0x20
    Opening file: pcieg3fw.bin
    Updating PCIE firmware
    ........................................................................................................................ Done
    PCIE firmware updated successfully. Please reset the system...
    
    SAI.0> ::exit
    
    root@s5200-switch-console:/home/admin#
    
    root@s5200-switch-console:/home/admin# ipmitool chassis power cycle
    Chassis Power Control: Cycle
    11, 32, 15, 00068001, 19, 00068000,
    
    
    BIOS Boot Selector for S5200
    Version 3.40.0.9-15
    
    
    POST Configuration
    CPU Signature 506F1
    CPU FamilyID=6, Model=5F, SteppingId=1, Processor=0
    Microcode Revision 38
    Platform ID: 0x0
    PMG_CST_CFG_CTL: 0x37
    Misc EN: 0x840089
    Gen PM ConA: 0xA0800200
    Therm Status: 0x8000000
    POST Control=0xEA000301, Status=0xE604FF00
    
    BIOS initializations...
    
    CPGC Memtest Channel 0 ......................
    
        
  11. Bekræft PCIe-firmwareversionen efter opgraderingen, skriv: sudo hshell -c 'pciephy fw version'.
    Eksempel på output:
    0:soc_flash_init: Flash supported ID = 0x20
    PCIe FW loader version: 2.6
    PCIe FW version: D102_0A

Additional Information

Affected Products

ScaleIO
Article Properties
Article Number: 000315118
Article Type: How To
Last Modified: 30 أبريل 2025
Version:  1
Find answers to your questions from other Dell users
Support Services