VxRail: VxRail-klusteri ei näy APEX AIOps -havainnoinnissa
Summary: VxRail: Klusteri ei näy APEX AIOps -havaittavuudessa.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
VxRail-kohde S/N ei näy järjestelmänvalvojan >yhteyksissä
Esimerkki: VxRail-klustereita on kaksi. Mutta se näyttää vain yhden klusterin.

/var/log/mystic/telemetry/adc.log
Capacity prestore -laajennusvirhe:
2025-06-12 02:13:07,783 [ERROR] <MainThread:140243648866112>-[collect_disk_capacity.py:<module>():116]-'NoneType' object has no attribute 'get'
Traceback (most recent call last):
File "/mystic/telemetry/DCManager/ADC/../ADC/plugins/collect_disk_capacity.py", line 114, in <module>
main()
File "/mystic/telemetry/DCManager/ADC/../ADC/plugins/collect_disk_capacity.py", line 35, in main
capacity_entities = capacity_summary.get('capacity')
AttributeError: 'NoneType' object has no attribute 'get'
2025-06-12 02:13:07,855 [ERROR] <ThreadPoolExecutor-2_0:140390938179328>-[ExecutionPool.py:run_capacity_pre_store():59]-[Process Pool] capacity pre-store plugin error: Command '['/bin/sh', '-c', '/mystic/telemetry/DCManager/ADC/../venv/bin/python /mystic/telemetry/DCManager/ADC/../ADC/plugins/collect_disk_capacity.py']' returned non-zero exit status 1.
Virtatietovirhe:
2025-06-12 02:03:08,590 [INFO] <MainThread:139812633392960>-[collect_power.py:<module>():136]-[Power collector] start collecting power ... 2025-06-12 02:03:08,590 [INFO] <MainThread:139812633392960>-[collect_power.py:is_linzhi_supported():104]-vxm_verion: 8.0.110 2025-06-12 02:03:08,590 [ERROR] <MainThread:139812633392960>-[myutils.py:load_json_data():55]-Load json: Expecting value: line 1 column 1 (char 0) 2025-06-12 02:03:08,590 [ERROR] <MainThread:139812633392960>-[collect_power.py:main():99]-Failed to collect power data. Error: 'NoneType' object has no attribute 'get'
Cause
Active Direct Connector (ADC) -määritystiedosto /mystic/telemetry/DCManager/ADC/plugins/capacity.json on tyhjä.
Active Direct Connector (ADC) -määritystiedosto /mystic/telemetry/DCManager/ADC/plugins/power_stats.json on tyhjä.
Resolution
1. Muokkaa tiedostoa /mystic/telemetry/DCManager/ADC/plugins/capacity.jsonja muuta sisältöä seuraavasti:
# cat /mystic/telemetry/DCManager/ADC/plugins/capacity.json
{
"capacity": {
}
}
2. Muokkaus /mystic/telemetry/DCManager/ADC/plugins/power_stats.jsonja muuta sisältöä seuraavasti:
# cat /mystic/telemetry/DCManager/ADC/plugins/power_stats.json
{
"power_consumed": {
}
}Affected Products
VxRail, CloudIQArticle Properties
Article Number: 000337427
Article Type: Solution
Last Modified: 13 فبراير 2026
Version: 2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.