VxRail: O cluster do VxRail não é exibido na capacidade de observação do APEX AIOps

Summary: VxRail: O cluster não é exibido na Observabilidade do APEX AIOps.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

O S/N de destino do VxRail não é exibido no Exemplo de conectividade

do administrador>: Há dois clusters do VxRail. Mas mostra apenas um cluster.

dois VxRail Clusters, mas apenas um cluster mostra

/var/log/mystic/telemetry/adc.log

Erro no plug-in Capacity prestore:

2025-06-12 02:13:07,783 [ERROR] <MainThread:140243648866112>-[collect_disk_capacity.py:<module>():116]-'NoneType' object has no attribute 'get'
Traceback (most recent call last):
  File "/mystic/telemetry/DCManager/ADC/../ADC/plugins/collect_disk_capacity.py", line 114, in <module>
    main()
  File "/mystic/telemetry/DCManager/ADC/../ADC/plugins/collect_disk_capacity.py", line 35, in main
    capacity_entities = capacity_summary.get('capacity')
AttributeError: 'NoneType' object has no attribute 'get'
2025-06-12 02:13:07,855 [ERROR] <ThreadPoolExecutor-2_0:140390938179328>-[ExecutionPool.py:run_capacity_pre_store():59]-[Process Pool] capacity pre-store plugin error: Command '['/bin/sh', '-c', '/mystic/telemetry/DCManager/ADC/../venv/bin/python /mystic/telemetry/DCManager/ADC/../ADC/plugins/collect_disk_capacity.py']' returned non-zero exit status 1.

Erro de dados de energia:

2025-06-12 02:03:08,590 [INFO] <MainThread:139812633392960>-[collect_power.py:<module>():136]-[Power collector] start collecting power ...
2025-06-12 02:03:08,590 [INFO] <MainThread:139812633392960>-[collect_power.py:is_linzhi_supported():104]-vxm_verion: 8.0.110
2025-06-12 02:03:08,590 [ERROR] <MainThread:139812633392960>-[myutils.py:load_json_data():55]-Load json: Expecting value: line 1 column 1 (char 0)
2025-06-12 02:03:08,590 [ERROR] <MainThread:139812633392960>-[collect_power.py:main():99]-Failed to collect power data. Error: 'NoneType' object has no attribute 'get'

Cause

Arquivo de configuração do Active Directly Connector (ADC) /mystic/telemetry/DCManager/ADC/plugins/capacity.json está vazio. 

Arquivo de configuração do Active Directly Connector (ADC) /mystic/telemetry/DCManager/ADC/plugins/power_stats.json está vazio.

Resolution

1. Editar arquivo /mystic/telemetry/DCManager/ADC/plugins/capacity.jsone altere o conteúdo como:

# cat /mystic/telemetry/DCManager/ADC/plugins/capacity.json
{
    "capacity": {
    }
}

2. Edit /mystic/telemetry/DCManager/ADC/plugins/power_stats.jsone altere o conteúdo como:

# cat /mystic/telemetry/DCManager/ADC/plugins/power_stats.json
{
    "power_consumed": {
    }
}

Affected Products