PowerFlex 4.X: How to Power-On after Unexpected Power Loss

Summary: This section is to assist you in responding to unexpected power loss. This Article is a general guideline and has not been tested in every scenario. If at any point there is a failure, contact Dell Technologies Support. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

Note: These guidelines have not been tested in every scenario, and it is recommended to contact Dell Support if you encounter any failures or uncertainties.
 
  • PowerFlex management cluster (KVM)

The PowerFlex management cluster (KVM) feature is considered as technology preview. Contact PowerFlex product management for details on this option.

Management
  • Power on the switches
    • On all switches, confirm Green status lights
    • For out-of-band management switches, log in and confirm:
      • Validate the configuration, type 
        show running-configuration
      • Validate uplinks, type 
        show interface brief
      • Validate iDRAC connectivity, type 
        show interface brief
      • Validate swtich hardware, type
         show hardware (cisco only)
    • For non-management switches, log in and confirm:
      • Validate the configuration, type 
        show running-configuration
      • Validate uplinks, type 
        show interface brief
      • Validate port channels, type 
        show port-channel summary
      • Validate switch hardware, type 
        show hardware (cisco only)
  • Power on the management nodes
    • Confirm the status LED indicator light is off on each management node. The light on the front of the node should not be blinking amber. See for more information.
    • Log in to each iDRAC to confirm no hardware alarms or errors and confirm the OS booted successfully.
  • Verify the following in the management PowerFlex Manager:
    • Check alerts: Go to Monitoring > Alerts.
    • Check management diagnostic status (for PowerFlex 4.8 and above), and ensure all statuses are green.
      • Go to Monitoring > Management Diagnostics.
      • Run all management diagnostic tests.
    • SDS
      • Go to Block > SDSs.
      • Ensure the state is Healthy.
      • Ensure the connected state is Connected.
    • SDC
      • Go to Block > Hosts.
      • Ensure the connected state is Connected.
    • Verify health of resources: Go to the Resources tab and confirm the Health Status.

 

Production

  • Log in to each production PowerFlex Manager.
  • Check alerts: Go to Monitoring > Alerts.
  • Check management diagnostic status (for PowerFlex Manager 4.8 and above), and ensure all statuses are green.
    • Go to Monitoring > Management Diagnostics.
    • Run all management diagnostic tests.
  • SDS
    • Go to Block > SDSs.
    • Ensure the state is Healthy.
    • Ensure the connected state is Connected.
  • SDC
    • Go to Block > Hosts.
    • Ensure the connected state is Connected.
  • Verify health of resources: Go to the Resources tab and confirm the Health Status.
  • Verify power on the storage-only nodes, using the PowerFlex Manager storage only resource group to identify nodes. Ensure the resource group is healthy.
  • Verify power on the hyperconverged nodes, using the PowerFlex Manager storage only resource group to identify nodes. Ensure the resource group is healthy.
  • Verify power on compute-only nodes, using the PowerFlex Manager storage only resource group to identify nodes. Ensure the resource group is healthy.
  • If applicable, verify replication status using PowerFlex Manager.

==========================================================================================

  • Integrated PowerFlex management (KVM)

 

Management
  • PDUs powered on
  • Power on the switches
    • On all switches, confirm Green status lights
    • For out-of-band management switches, log in and confirm:
      • Validate the configuration, type show 
        running-configuration
      • Validate uplinks, type 
        show interface brief
      • Validate iDRAC connectivity, type 
        show interface brief
      • Validate swtich hardware, type 
        show hardware (cisco only)
    • For non-management switches, log in and confirm:
      • Validate the configuration, type
         show running-configuration
      • Validate uplinks, type 
        show interface brief
      • Validate port channels, type 
        show port-channel summary
      • Validate switch hardware, type 
        show hardware (cisco only)
  • Power on all nodes
    • Confirm the status LED indicator light is off on each management node. The light on the front of the node should not be blinking amber. See for more information.
    • Log in to each iDRAC to confirm no hardware alarms or errors and confirm the OS booted successfully.
    • After 15 minutes, log in to PowerFlex Manager.

 

Production
  • Verify power on the storage-only nodes, using the PowerFlex Manager storage only resource group to identify nodes. Ensure the resource group is healthy.
  • Verify power on the hyperconverged nodes, using the PowerFlex Manager storage only resource group to identify nodes. Ensure the resource group is healthy.
  • Verify power on compute-only nodes, using the PowerFlex Manager storage only resource group to identify nodes. Ensure the resource group is healthy.
  • If applicable, verify replication status using PowerFlex Manager. Go to Protection > Overview.
  • If applicable, verify CloudLink status using PowerFlex Manager. Go to Resource Group > Overview.

=======================================================================================

  • PowerFlex management cluster (ESXi)

Checklist for the PowerFlex management cluster (ESXi).

Management
  • PDUs powered on
  • Power on the switches
    • On all switches, confirm Green status lights
    • For out-of-band management switches, log in and confirm:
      • Validate the configuration, type 
        show running-configuration
      • Validate uplinks, type 
        show interface brief
      • Validate iDRAC connectivity, type 
        show interface brief
      • Validate swtich hardware, type 
        show hardware (cisco only)
    • For non-management switches, log in and confirm:
      • Validate the configuration, type
         show running-configuration
      • Validate uplinks, type 
        show interface brief
      • Validate port channels, type
         show port-channel summary
      • Validate switch hardware, type 
        show hardware (cisco only)
  • Power on the management nodes
    • Confirm the status LED indicator light is off on each management node. The light on the front of the node should not be blinking amber. See for more information.
    • Log in to each iDRAC to confirm no hardware alarms or errors and confirm the OS booted successfully.
    • Log in to each VMware ESXi host using the web client and ensure all storage virtual machines are booted.
      • Navigate to Virtual Machines and confirm the storage virtual machine is powered on. If not, power it on.
      • Allow PowerFlex storage to boot before you continue.
    • Ensure all management virtual machines are started, and if not, power them on:
      • CloudLink
      • Secure connect gateway
      • Jump server
      • VMware vCenter
      • Management virtual machines
      • Customer workloads
    • After 15 minutes, log in to PowerFlex Manager.
  • Verify the following in PowerFlex Manager:
    • Check alerts: Go to Monitoring > Alerts.
    • Check management diagnostic status (for PowerFlex Manager 4.8 and above), and ensure all statuses are green.
      • Go to Monitoring > Management Diagnostics.
      • Run all management diagnostic tests.
    • SDS
      • Go to Block > SDSs.
      • Ensure the state is Healthy.
      • Ensure the connected state is Connected.
    • SDC
      • Go to Block > Hosts.
      • Ensure the connected state is Connected.
    • Verify health of resources: Go to the Resources tab and confirm the Health Status.

 

Production
  • Verify power on the storage-only nodes, using the PowerFlex Manager storage only resource group to identify nodes. Ensure the resource group is healthy.
  • Verify power on the hyperconverged nodes, using the PowerFlex Manager storage only resource group to identify nodes. Ensure the resource group is healthy.
  • Verify power on compute-only nodes, using the PowerFlex Manager storage only resource group to identify nodes. Ensure the resource group is healthy.
  • If applicable, verify replication status using PowerFlex Manager. Go to Protection > Overview.
  • If applicable, verify CloudLink status using PowerFlex Manager. Go to Resource Group > Overview.

==========================================================================================

  • Single ESXi PowerFlex management node
Management
  • PDUs powered on
  • Power on the switches
    • On all switches, confirm Green status lights
    • For out-of-band management switches, log in and confirm:
      • Validate the configuration, type 
        show running-configuration
      • Validate uplinks, type 
        show interface brief
      • Validate iDRAC connectivity, type 
        show interface brief
      • Validate swtich hardware, type 
        show hardware (cisco only)
    • For non-management switches, log in and confirm:
      • Validate the configuration, type 
        show running-configuration
      • Validate uplinks, type 
        show interface brief
      • Validate port channels, type 
        show port-channel summary
      • Validate switch hardware, type 
        show hardware (cisco only)
  • Power on the management nodes
    • Confirm the status LED indicator light is off on each management node. The light on the front of the node should not be blinking amber. See for more information.
    • Log in to each iDRAC to confirm no hardware alarms or errors and confirm the OS booted successfully.
    • Log in to each VMware ESXi host using the web client and ensure all storage virtual machines are booted.
      • Navigate to Virtual Machines and confirm the storage virtual machine is powered on. If not, power it on.
      • Allow PowerFlex storage to boot before you continue.
    • Ensure all management virtual machines are started, and if not, power them on:
      • CloudLink
      • Secure connect gateway
      • Jump server
      • VMware vCenter
      • Management virtual machines
      • Customer workloads
    • After 15 minutes, log in to PowerFlex Manager.
  • Verify the following in PowerFlex Manager:
    • Check alerts: Go to Monitoring > Alerts.
    • Check management diagnostic status (for PowerFlex Manager 4.8 and above), and ensure all statuses are green.
      • Go to Monitoring > Management Diagnostics.
      • Run all management diagnostic tests.
    • SDS
      • Go to Block > SDSs.
      • Ensure the state is Healthy.
      • Ensure the connected state is Connected.
    • SDC
      • Go to Block > Hosts.
      • Ensure the connected state is Connected.
    • Verify health of resources: Go to the Resources tab and confirm the Health Status.

 

Production
  • Verify power on the storage-only nodes, using the PowerFlex Manager storage only resource group to identify nodes. Ensure the resource group is healthy.
  • Verify power on the hyperconverged nodes, using the PowerFlex Manager storage only resource group to identify nodes. Ensure the resource group is healthy.
  • Verify power on compute-only nodes, using the PowerFlex Manager storage only resource group to identify nodes. Ensure the resource group is healthy.
  • If applicable, verify replication status using PowerFlex Manager. Go to Protection > Overview.
  • If applicable, verify CloudLink status using PowerFlex Manager. Go to Resource Group > Overview.

Products

PowerFlex Appliance, ScaleIO, PowerFlex rack RCM Software
Article Properties
Article Number: 000376693
Article Type: How To
Last Modified: 28 يوليو 2026
Version:  3
Find answers to your questions from other Dell users
Support Services