PowerEdge: Firmware update may fail on 16G/17G servers with 'USBNet is disabled' error

Summary: Firmware updates performed on 16G/17G servers from a supported operating system (OS) may fail under certain conditions, displaying the error: 'USBNet is disabled. Please enable USBNet and try the update again.' ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Updates performed using Dell Update Package (DUP) may fail and report the error 'USBNet is disabled. Please enable USBNet and try update again' in the conditions described below.

 

  • Update is performed in 17G servers or few components firmware on 16G servers
  • DUP-based update is performed in the Operating system.
  • USB NIC pass-through is disabled in iDRAC.
  • DUP is created using framework version '25.08.01 Build 997'. 

Cause

The Dell Update Package (DUP) is designed to temporarily enable USB NIC pass-through during updates; however, this feature is not functioning correctly in specific Framework versions. 

Resolution

Workaround:  

Enable USB-NIC passthrough in iDRAC manually from Idrac UI or Racadm CLI before the update is performed.

Solution:  DUP created using newer version of framework or previous version of framework do not have this issue.

 

DUP framework can be identified using methods.

  • Windows - Right click the DUP exe and check the "Details" tab under properties
  • Linux - DUP.bin -fv 

Additional Information

Firmware update fails to complete, USBNet is disabled, 25.08.01, JIT-366646.

Videos

Manually enable USB NIC pass-through in iDRAC using either the iDRAC UI or the Racadm CLI before performing the update.

 

Racadm command to enable USB NIC Pass-through, 'racadm set idrac.os-bmc.UsbP2PEnable Enabled'

Racadm command to disable USB NIC pass-through 'racadm set idrac.os-bmc.UsbP2PEnable Disabled'

Other methods to manually enable or disable USB NIC pass-through can be found in the Idrac User guide.

Solution:  DUPs created with either newer or earlier versions of the Framework do not exhibit this issue.

DUP framework can be identified using methods.

Windows - Right click the DUP exe and check the "Details" tab under properties

Linux - DUP.bin -fv