DSA-2026-064: Security Update for PowerFlex Appliance Multiple Vulnerabilities

Summary: PowerFlex Appliance remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Impact

Critical

Details

Third-party Component CVEs More Information
Dell PowerEdge Server BIOS CVE-2023-31351, CVE-2024-21953, CVE-2024-21965, CVE-2024-36331, CVE-2024-21977, CVE-2024-36354, CVE-2025-0032, CVE-2025-20053, CVE-2025-24305, CVE-2025-21090, CVE-2025-20613, CVE-2025-21096, CVE-2025-22853, CVE-2025-20037, CVE-2025-20067, CVE-2025-22392, CVE-2025-20077, CVE-2025-20064, CVE-2025-20068, CVE-2025-20105, CVE-2025-20028, CVE-2025-20027, CVE-2025-20005, CVE-2025-20073, CVE-2025-0033, CVE-2025-29943, CVE-2025-29934, CVE-2024-42446, CVE-2025-22885, CVE-2023-31364 DSA-2025-298, DSA-2025-297, DSA-2025-352, DSA-2025-351, DSA-2025-350, DSA-2025-370, DSA-2026-011, DSA-2026-075
TPM CVE-2025-2884, CVE-2026-6923 DSA-2025-232, DSA-2026-224
Intel CVE-2025-24486, CVE-2025-25273, CVE-2025-21086, CVE-2025-26863, CVE-2025-26697, CVE-2025-24511 https://nvd.nist.gov/vuln/search This hyperlink is taking you to a website outside of Dell Technologies.
kernel CVE-2026-31431 https://nvd.nist.gov/vuln/search This hyperlink is taking you to a website outside of Dell Technologies.
open ssh CVE-2025-61984 https://nvd.nist.gov/vuln/search This hyperlink is taking you to a website outside of Dell Technologies.
java CVE-2025-50106, CVE-2025-30749 https://nvd.nist.gov/vuln/search This hyperlink is taking you to a website outside of Dell Technologies.
netty CVE-2025-55163, CVE-2025-58057 https://nvd.nist.gov/vuln/search This hyperlink is taking you to a website outside of Dell Technologies.
commons-lang3 CVE-2025-48924 https://nvd.nist.gov/vuln/search This hyperlink is taking you to a website outside of Dell Technologies.
angus_smtp CVE-2025-7962 https://nvd.nist.gov/vuln/search This hyperlink is taking you to a website outside of Dell Technologies.
quarkus-vertx CVE-2025-49574 https://nvd.nist.gov/vuln/search This hyperlink is taking you to a website outside of Dell Technologies.
urllib3 CVE-2025-50181 https://nvd.nist.gov/vuln/search This hyperlink is taking you to a website outside of Dell Technologies.
Keycloak CVE-2024-8176, CVE-2025-53066, CVE-2025-58187, CVE-2025-58188, CVE-2025-59250, CVE-2025-59375, CVE-2025-61723, CVE-2025-61725, CVE-2025-9086, CVE-2025-9187, CVE-2025-9230, CVE-2025-9162, CVE-2025-8419, CVE-2025-7784, CVE-2025-7365 https://nvd.nist.gov/vuln/search This hyperlink is taking you to a website outside of Dell Technologies.

Proprietary Code CVEs Description CVSS Base Score CVSS Vector String
CVE-2026-22283 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Inclusion of Functionality from Untrusted Control Sphere vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure. 7.5 CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H  This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-40641 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Use of a Broken or Risky Cryptographic Algorithm vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and Information tampering. 4.8 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-35069 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with adjacent network access could potentially exploit this vulnerability, leading to Script injection. 5.7 CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-35068 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with adjacent network access could potentially exploit this vulnerability, leading to information disclosure. 3.5 CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-35066 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Access Control vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to denial of service. 7.1 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-35067 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Access Control vulnerability. A low privileged attacker with adjacent network access could potentially exploit this vulnerability, leading to Elevation of privileges and Unauthorized access. 5.7 CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-35162 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Access Control vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to denial of service. 4.3 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-35065 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Code execution, Denial of service, Information disclosure, Information tampering, Remote execution, Script injection, and Unauthorized access. 8.8 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-32804 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Authentication vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Unauthorized access. 8.1 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-49502 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Authentication vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure, Information tampering, and Unauthorized access. 7.4 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2024-47477 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain an improper certificate validation vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability leading to man-in-the-middle attack in tandem with DNS cache poisoning. 6.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-56690 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure, Information exposure, and Unauthorized access. 8.5 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-56689 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure. 7.7 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-56688 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure. 9.1 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H This hyperlink is taking you to a website outside of Dell Technologies.

 

Proprietary Code CVEs Description CVSS Base Score CVSS Vector String
CVE-2026-22283 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Inclusion of Functionality from Untrusted Control Sphere vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure. 7.5 CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H  This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-40641 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Use of a Broken or Risky Cryptographic Algorithm vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and Information tampering. 4.8 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-35069 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with adjacent network access could potentially exploit this vulnerability, leading to Script injection. 5.7 CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-35068 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with adjacent network access could potentially exploit this vulnerability, leading to information disclosure. 3.5 CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-35066 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Access Control vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to denial of service. 7.1 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-35067 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Access Control vulnerability. A low privileged attacker with adjacent network access could potentially exploit this vulnerability, leading to Elevation of privileges and Unauthorized access. 5.7 CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-35162 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Access Control vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to denial of service. 4.3 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-35065 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Code execution, Denial of service, Information disclosure, Information tampering, Remote execution, Script injection, and Unauthorized access. 8.8 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-32804 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Authentication vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Unauthorized access. 8.1 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-49502 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Authentication vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure, Information tampering, and Unauthorized access. 7.4 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2024-47477 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain an improper certificate validation vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability leading to man-in-the-middle attack in tandem with DNS cache poisoning. 6.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-56690 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure, Information exposure, and Unauthorized access. 8.5 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-56689 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure. 7.7 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N This hyperlink is taking you to a website outside of Dell Technologies.
CVE-2026-56688 Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure. 9.1 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H This hyperlink is taking you to a website outside of Dell Technologies.

 

Dell Technologies recommends all customers consider both the CVSS base score and any relevant temporal and environmental scores that may impact the potential severity associated with a particular security vulnerability.

Affected Products & Remediation

Product  Software / Firmware Affected Versions  Remediated Versions  Link
PowerFlex Appliance IC Versions prior to 51.391.00 Version 51.391.01 or later IC release
PowerFlex Appliance IC Versions prior to 48.384.01 Version 51.384.01 or later IC release
Product  Software / Firmware Affected Versions  Remediated Versions  Link
PowerFlex Appliance IC Versions prior to 51.391.00 Version 51.391.01 or later IC release
PowerFlex Appliance IC Versions prior to 48.384.01 Version 51.384.01 or later IC release

In the case of manual upgrade for PowerFlex Appliance, please see this link: https://www.dell.com/support/product-details/en-us/product/powerflex-appliance-int-ca-sw/drivers.

Revision History

Revision Date Description 
1.0 2026-06-15Initial release 
2.02026-06-15Updated for enhanced presentation with no changes to content
3.02026-07-10Added details for CVE-2026-22283, CVE-2026-40641, CVE-2026-35069, CVE-2026-35068, CVE-2026-35066, CVE-2026-35067, CVE-2026-35162, CVE-2026-35065, CVE-2026-32804, CVE-2026-49502, CVE-2024-47477, CVE-2026-56688, CVE-2026-56689, CVE-2026-56690
4.02026-07-10Updated for enhanced presentation with no changes to content

Related Information

Affected Products

PowerFlex Appliance, ScaleIO, PowerFlex appliance Intelligent Catalog Software
Article Properties
Article Number: 000477555
Article Type: Dell Security Advisory
Last Modified: 09 يوليو 2026
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.